Keyword: ion-source
Paper Title Other Keywords Page
TUXO01 Coupling Microwave Power into ECR Ion Source Plasmas at Frequencies above 20 GHz plasma, ECR, ion, coupling 1
 
  • C.M. Lyneis, J.Y. Benitez, M.M. Strohmeier, D.S. Todd
    LBNL, Berkeley, California, USA
 
  Electron Cyclotron Resonance (ECR) ion sources have been built to operate at frequencies from 5 GHz to 28 GHz and typically use a plasma chamber that serves as a multi-mode cavity. For small sources operating at 6 to 14 GHz cavity mode-like behavior has been reported. In these cavities the vacuum mode density is low enough that it may be that the RF power distribution can be understood in terms of excitation of a few modes. The large superconducting ECR ion sources, such as VENUS, operating at higher frequencies have a much greater mode density and very strong damping from plasma microwave adsorption. In this type of source, how the RF is launched into the plasma chamber will strongly affect the microwave coupling and the chamber walls will be less important. The VENUS source uses round over-moded TE01 mode waveguide to couple to the plasma, while most modern fusion devices use quasi-gaussian HE11 waves for injection into plasmas. In this paper we will describe the potential advantages of applying this technology to superconducting ECR ion sources as well as designs for doing so with VENUS.  
slides icon Slides TUXO01 [18.302 MB]  
 
TUXO02 An Experimental Study of ECRIS Plasma Stability and Oscillation of Beam Current ECR, plasma, ion, ECRIS 5
 
  • O.A. Tarvainen, T. Kalvas, H. A. Koivisto, J.P.O. Komppula, V. Toivanen
    JYFL, Jyväskylä, Finland
  • C.M. Lyneis, M.M. Strohmeier
    LBNL, Berkeley, California, USA
 
  The stability of oxygen ion beams extracted from ECR ion sources has been studied with the superconducting ion source VENUS at LBNL and with the A-ECR type 14 GHz ECRIS at JYFL. Discrete Fourier transform has been used for characterizing beam current oscillations in kHz range exhibited by both ion sources. The effect of source parameters on the frequency and amplitude of the oscillations is discussed. It was found that double frequency heating affects the oscillation frequency, biased disc can be used to mitigate the amplitude of beam current fluctuations, increasing B-minimum results to pronounced instabilities and operating the ion source with significantly higher mirror ratio than suggested by ECRIS scaling laws yields the most stable ion beams. It is argued that the observed beam current fluctuations are correlated with plasma instabilities. A 'roadmap' for identifying the plasma instability mechanisms responsible for beam current fluctuations is presented.  
slides icon Slides TUXO02 [2.195 MB]  
 
TUXO03 Two-frequency Heating Technique for Stable ECR Plasma plasma, ion, ECR, ECRIS 10
 
  • A. Kitagawa, M. Muramatsu
    NIRS, Chiba-shi, Japan
  • S. Biri, R. Rácz
    ATOMKI, Debrecen, Hungary
  • T.F. Fujita
    National Institute of Radiological Sciences, Chiba, Japan
  • Y. Kato
    Osaka University, Graduate School of Engineering, Osaka, Japan
  • N. Sasaki, W. Takasugi
    AEC, Chiba, Japan
 
  As a method to improve highly charged ion production, a technique to feed multiple microwaves with different frequencies is well-known. However the reason is not made sufficiently clear. Our group studied with two frequencies close together with a power of 600 W over by 18 GHz NIRS-HEC ECR ion source installed in the Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences (NIRS). As a result, it was revealed that the improvement of output beam current depends on the total power. In this case it seems that the two-frequency heating technique carries the advantage that the plasma instability at high microwave power is relieved. The effectiveness of an additional microwave depends on its frequency. It is necessary to optimize an additional frequency precisely; several tens MHz step against 18 GHz. The optimized frequency is directly influenced by the magnetic configuration. The necessary requirements for an additional microwave and the procedure of optimization in order to obtain a large advantage will be discussed.  
slides icon Slides TUXO03 [1.590 MB]  
 
TUYO02 Control of the Plasma Transversal Losses, Caused by MHD Instabilities, in Open Mirror Magnetic Trap of the ECRIS: Recent Experiments on SMIS 37 Setup plasma, ion, ECR, electron 18
 
  • V. Sidorov, I. Izotov, S. Razin, V. Skalyga, V. Zorin
    IAP/RAS, Nizhny Novgorod, Russia
 
  Funding: This work was partially performed in the framework of the Federal Targeted Program 'Scientific and Educational Personnel of the Innovative Russia' for 2009-2013
This work is a continuation of the experiments described in [1, 2] and aimed at the investigation of the new conceptions of MHD stabilization of plasma in open axisymmetric traps, specifically, it is aimed at the investigation of the shear flow influence on the transport control in open mirror traps. As in previous experiments, shear flow was created by limiter-electrode with bias potential according to the vacuum chamber. Plasma density structure in radial and azimuthal directions was studied. Mode structure of the perturbations was investigated. Substantial sharp shift of the plasma density maximum to the system axis with bias potential growth was demonstrated. It was shown, that the value of the bias potential that corresponds to the plasma density profile shift grows with the magnetic field growth that can be interpreted as the electron temperature growth. Some theoretical estimations of the influence of the transversal losses decrease on plasma parameters were made.
[1] A.Sidorov, P.Bagryansky, A.Beklemishev et al. Trans. Fusion Sci. and Technology, 59, 112, (2011).
[2] I.Izotov, S.Razin, A.Sidorov et al. Rev. Sci. Instrum., 83, 02A318 (2012).
 
slides icon Slides TUYO02 [1.542 MB]  
 
TUZO02 Detailed Investigation of the 4D Phase-Space of an Ion Beam ion, emittance, dipole, cyclotron 30
 
  • H.R. Kremers, J.P.M. Beijers, S. Brandenburg, V. Mironov, S. Saminathan
    KVI, Groningen, The Netherlands
 
  A second order transfer matrix is calculated, which is used in the calculation of a 4D phase-space distribution of a 24.6 keV He1+ beam. The calculated distribution matches a 4D phase-space distribution measured with the KVI pepper pot emittance meter. The pepper pot emittance meter is installed in the image plane of a dipole magnet acting as a charge-state analyser directly downstream the KVI AECR ion source. From the second order transfer matrix simple analytical equations are derived by retaining the terms for angular coefficients. These simple equations describe the main features of the phase-space correlations in the image plane. The equations show also that the subset of the 4D phase-space distribution, selected by one pepper pot aperture, results in multiple beam-lets. Due to this successful matrix modelling we conclude that the 4D phase-space distribution measured is fully determined by the ionoptical properties of the magnet.  
slides icon Slides TUZO02 [6.348 MB]  
 
TUPP01 Quantitative Determination of 146Sm/147Sm Ratios by Accelerator Mass Spectrometry with an ECR Ion Source and Linear Acceleration for 146Sm Half-Life Measurement ion, ECR, detector, target 43
 
  • N. Kinoshita
    UTTAC, Tsukuba, Ibaraki, Japan
  • P. Collon, Y. Kashiv, D. Robertson, C.J. Schmitt, X.D. Tang
    University of Notre Dame, Indiana, USA
  • C. Deibel
    MSU, East Lansing, Michigan, USA
  • C. Deibel, B. DiGiovine, J.P. Greene, D. Henderson, C.L. Jiang, S.T. Marley, R.C. Pardo, E. Rehm, R.H. Scott, R.C. Vondrasek
    ANL, Argonne, USA
  • T. Nakanishi, A. Yokoyama
    Kanazawa University, Kanazawa, Japan
  • M. Paul
    The Hebrew University of Jerusalem, The Racah Institute of Physics, Jerusalem, Israel
 
  Funding: Supported by U.S. DOE, Office of Nuclear Physics, contract No. DE-AC02-06CH11357, NSF JINA Grant Nr. PHY0822648 and Science Research Prog. of Japan Society for the Promotion of Science (20740161)
The alpha-decaying 146Sm nuclide is used for chronology of the Solar System and silicate mantle differentiation in planets. We performed a new determination of 146Sm half-life by measuring 146Sm/147Sm alpha activity and atom ratios in 147Sm activated via (g,n), (n,2n) and (p,2n) reactions and obtained a value (68 Myr), smaller than that adopted so far (103 Myr), with important geochemical implications*. The experiment required determination of 146Sm/147Sm ratios by high-energy (6 MeV/u) accelerator mass spectrometry to discriminate 146Sm from isobaric 146Nd contaminant. Activated Sm targets were dissolved, chemically purified and reconverted to metallic Sm. Sputter cathodes, made by pressing the Sm metal into high-purity Al holders, were used to feed the Argonne ECR ion source. 146Sm22+, 147Sm22+ ions were alternately injected and accelerated with the ATLAS linac by proper scaling of ion source and accelerator components. A tightly-fitted quartz cylindrical liner was inserted in the ECR plasma chamber to reduce contamination from the walls. 146Sm ions were eventually counted in a gas-filled magnet and 147Sm ions either measured as charge current or counted after proper attenuation.
* N. Kinoshita et al., Science 334, 1614 (2012)
 
 
TUPP03 Integration of a Third Ion Source for Heavy Ion Radiotherapy at HIT ion, operation, extraction, emittance 46
 
  • T.W. Winkelmann, A.B. Büchel, R. Cee, A. Gaffron, Th. Haberer, J.M. Mosthaf, B. Naas, A. Peters, J. Schreiner
    HIT, Heidelberg, Germany
 
  HIT is the first European hospital based facility for scanned proton and heavy ion radiotherapy. In 2009 the clinical operation started, since then more than 800 patients were treated in the facility. In a 24/7 operation scheme two 14.5 GHz electron cyclotron resonance ion sources are routinely used to produce protons and carbon ions. In the near future a helium beam for regular patient treatment is requested. The modification of the low energy beam transport line (LEBT) for the integration of a third ion source into the production facility was done in winter 2011. For beam quality improvement with a smaller emittance at the same current we designed and tested a new extraction system at the testbench and equipped the source for protons and helium with this optimized system. This paper will present results of the LEBT modification and gives an outlook to further enhancements at the HIT ion source testbench.  
 
TUPP04 Design of a Compact ECR Ion Source for Various Ion Production ion, extraction, ECR, plasma 49
 
  • M. Muramatsu, S. Hojo, Y. Iwata, K. Katagiri, A. Kitagawa, Y. Sakamoto, S. Sato
    NIRS, Chiba-shi, Japan
  • A.G. Drentje
    KVI, Groningen, The Netherlands
  • T.F. Fujita
    National Institute of Radiological Sciences, Chiba, Japan
 
  Compact ECR ion source with all permanent magnets, so called Kei2, was developed for high energy carbon ion therapy facility at National Institute of Radiological Sciences. Kei2 source was design for production of only carbon ion for medical treatment. A copy of Kei2, so called KeiGM is used for Gunma University. Kei series are optimized for carbon ion production. In order to produce various ion beams for research, we design a new compact ECR ion source, so called Kei3. Kei3 is designed based on previous Kei series. In addition, there are three important points: 1) Movable beam extraction system for various extraction current densities, 2) An evaporator and MIVOC method for production of ions from solid materials and metal, and 3) Biased disk method and double frequency heating method for heavier ions. Same permanent magnets and microwave system will be used for easy maintenance and the cost effectiveness. Design of the Kei3 source will be described in this paper.  
 
TUPP17 Installation and Operation of a 28 GHz Gyrotron for the RIKEN Superconducting ECR Ion Source cathode, ion, detector, power-supply 71
 
  • J. Ohnishi, Y. Higurashi, T. Nakagawa
    RIKEN Nishina Center, Wako, Japan
 
  The RIKEN 28-GHz ECRIS uses a gyrotron microwave source fabricated by Mitsubishi Electric Corporation. The maximum output power is 10 kW. The gyrotron produces TE02-mode microwaves, which are converted into the TE01 mode by a mode converter. In the first test on the gyrotron performed using a dummy load, we observed the 50-300 Hz ripples of ~500 W in the output power of 1-7 kW, and it was difficult to make a stable operation in the low-power. These ripples were reduced to one-tenth by stabilizing the cathode voltage and then the gyrotron could produce microwaves from < 0.5 kW stably. The operation of the ion source with the 28 GHz gyrotron was started in 2011 and the ion source supplied U and Xe beams to the RIBF for two months. The power of the microwaves fluctuated slowly in the range of 870-1250 W, which influenced the beam current from the ion source. This fluctuation was caused by a slight change of the current of the solenoid of the gyrotron depending on the room temperature. We replaced the power supply with new one which has a current stability of 10ppm per day, and stabilized the microwave power in the range of 5% in the operation of 2 kW successfully.  
 
TUPP18 DECRIS-5 Ion Source for DC-110 Cyclotron Complex Results of the First Tests ion, injection, extraction, ECRIS 74
 
  • A.A. Efremov, V. Bekhterev, S.L. Bogomolov, Yu.K. Kostyukhov, N. Lebedev, V.N. Loginov, Yu. Yazvitsky
    JINR, Dubna, Moscow Region, Russia
  • V. Mironov
    KVI, Groningen, The Netherlands
 
  The project of the DC-110 cyclotron facility to provide applied research in the nanotechnologies (track pore membranes, surface modification of materials, etc.) has been designed by the Flerov Laboratory of Nuclear Reactions of the Joint Institute for Nuclear Research (Dubna). The facility includes the isochronous cyclotron DC-110 for accelerating the intense Ar, Kr, Xe ion beams with 2.5 MeV/nucleon fixed energy. The cyclotron is equipped with system of axial injection and ECR ion source DECRIS-5, operating at the frequency of 18 GHz. The main parameters of DECRIS-5 ion source and results of the first tests are presented in this report.  
 
WEYO02 Experimental Results: Charge-state and Current-density Distribution at the Plasma Electrode of an ECR Ion Source ion, plasma, extraction, ECR 101
 
  • L. Panitzsch, T. Peleikis, M. Stalder, R.F. Wimmer-Schweingruber
    IEAP, Kiel, Germany
 
  We have measured the current-density in very close vicinity (15 mm downstream) of the plasma electrode of our hexapole-geometry electron-cyclotron-resonance ion source (ECRIS). For this, we equipped our 3D-movable puller electrode with a customized Faraday Cup (FC) inside. To achieve high spatial resolution we reduced the aperture of the puller electrode to only 0.5 mm. Thus, the source-region of the extracted ion beam is limited to a very small area of the plasma electrode's hole (d = 4 mm). The information about the charge-state distribution and the current density in the plane of the plasma electrode is conserved in the ion beam and was scanned by remotely moving the small-aperture puller electrode (incl. FC) across the aperture of the plasma electrode. From additional m/q- measurements for the different positions we can deduce that different ion charge-states are grouped into bloated triangles of different sizes but with the same orientation in the plane of the plasma electrode with the current density peaking at the centre. This confirms simulations by various groups as well as some emittance measurements, but adds spatial resolution for the different charge-states.  
slides icon Slides WEYO02 [2.298 MB]  
 
WEYO03 Ion Beam Extraction from Magnetized Plasma plasma, ion, electron, extraction 106
 
  • P. Spädtke, R. Lang, J. Mäder, F. Maimone, J. Roßbach, K. Tinschert
    GSI, Darmstadt, Germany
 
  With increasing the total extracted current for any ion source, the optimisation of the extraction system becomes more important, because of the space charge effect. Several attempts have been made in the past to simulate the extraction from an Electron Cyclotron Resonance Ion Source (ECRIS) in a correct way. Most of these attempts failed, because they were not able to reproduce the experimental results. The best model up to now is given by the following procedure: tracing the magnetic field lines through the extraction aperture, looking where these field lines are coming from; using these coordinates of the magnetic field line as starting points for ions to be extracted; the initial current of each trajectory is determined by theoretical assumptions about the plasma or by a plasma simulation; Child's law is applicable locally only in direction of the magnetic field, if no emission limited flow is present.  
slides icon Slides WEYO03 [16.955 MB]  
 
WEZO02 Design of new 18 GHz ECR for RIKEN RIBF ion, plasma, ECRIS, solenoid 114
 
  • K. Ozeki, Y. Higurashi, T. Nakagawa, J. Ohnishi
    RIKEN Nishina Center, Wako, Japan
 
  In RIKEN RIBF, we plan to install a new 18 GHz ECR ion source, which supply the intense beam of highly charged heavy ion beam into the linear accelerator RILAC. By equipping two ion sources, it is expected to be able to develop new beams while we produce the beam for the experiment of RIBF. Based on the structure of 18 GHz ECR ion source which have been developed in RIKEN, this ion source has additional features as follows:
  1. Owing to three solenoid coils, Bext can be adjusted while Bmin is fixed to an optimum value.
  2. We adopt the variable frequency (17.2-18.4 GHz) RF power source. Therefore, further enhancement of the beam intensity is expected because the frequency band suited to a size of plasma chamber is selectable,
  3. In order to simplify the maintenance work, we improved a structure of the chamber.
In this contribution, we report the design of new ion source in detail.
 
slides icon Slides WEZO02 [10.113 MB]  
 
WEPP02 Relationship of Performance and RF Resonance Modes ion, ECR, resonance, plasma 121
 
  • T. Hattori, A. Kitagawa, M. Muramatsu
    NIRS, Chiba-shi, Japan
  • N. Hayashizaki
    RLNR, Tokyo, Japan
 
  The performance of Electron Cyclotron Resonance (ECR) ion source depends on the operation frequency, the magnetic mirror field, the maltipole field, the mirror ratio, the ECR zone and others. We studied the relationship of performance and operation frequency in ECR ion source (HiECR-3). The performance (beam intensity of Ar9+ ion) was measured according to change of frequency from 9.7 to 11.7 GHz in fixed magnetic field of HiECR ion source. We measured resonant frequencies of plasma chamber of HiECR ion source in condition of no plasma (current of mirror coils is zero). The data of intensity of Ar9+ related to measured resonant frequencies. Their resonant modes were checked with a 3D electromagnetic simulator (High Frequency Structure Simulator). As a result, it became clear that the performance of the ion source depends on electric-field distribution of the RF resonant mode.  
 
WEPP13 Development Update of the LECR4 Ion Source - Dragon at IMP ion, sextupole, ECR, extraction 133
 
  • W. Lu, B.H. Ma, L.T. Sun, H. Wang, D. Xie, X.Z. Zhang, H.W. Zhao
    IMP, Lanzhou, People's Republic of China
  • L. Ruan, B. Xiong
    IEE, Beijing, People's Republic of China
 
  A new room temperature ECR ion source, LECR4-DRAGON to operate at 18 GHz, is under development for the SSC-LINAC project at IMP. In comparison to other room temperature ECRISs, one unique feature of LECR4-DRAGON is that its plasma chamber is of ID 126 mm that is the biggest chamber for a room temperature ECRIS and the same as the superconducting ECR ion source SECRAL. Because the project funding requests testing a different magnet cooling scheme, solid quadrate copper coils cooled by medium evaporation at about 50oC are to be used to produce a maximum axial magnetic field of about 2.5 T at injection and 1.4 T at the extraction, which are similar to SECRAL operating at 18 GHz. Furthermore, a large bore non-Halbach permanent sextupole with staggered structure has been under fabrication which can produce a radial magnetic field reaching 1.5 T at the plasma chamber wall for operation at 18 GHz. The progress updates and discussions of this new ion source will be presented in this paper.  
 
WEPP14 An Advanced Injection System of Light Ions (AISLI) for Dielectric Wall Accelerator ion, proton, emittance, ECR 136
 
  • S.X. Peng, J. Chen, J.E. Chen, Z.Y. Guo, P.N. Lu, H.T. Ren, Y. Xu, J. Zhao
    PKU, Beijing, People's Republic of China
 
  The dielectric wall accelerator (DWA) is a kind of acceleration system that has the ability to accelerate any charge to mass ratio particle with high electric field gradients up to 400 MV/m and very compact dimension, for example d 30 mm x 50 mm. To demonstrate the high gradient tiny acceleration system, a comparable 50 mA/40 keV pulsed H+ converge beam injector is required. Based on the experimental results obtained on the test bench, a six electrodes injector was developed at Peking University (PKU). In this paper we will describe the preliminary experimental results as well as the details of the new compact injector which named as An Advanced Injector System of Light Ions (AISLI).  
poster icon Poster WEPP14 [3.963 MB]  
 
WEPP15 Metal Ion Beam Production with Improved Evaporation Ovens ion, operation, ECRIS, plasma 140
 
  • K. Tinschert, R. Lang, J. Mäder, F. Maimone, J. Roßbach
    GSI, Darmstadt, Germany
 
  Most of the ion beams delivered by the ECR ion sources at the GSI accelerator facilities are produced from materials in the solid state, which must be transformed into the gaseous state to feed the plasma. The well established method of thermal evaporation has been used by means of two types of resistively heated ovens for metals and solid compounds. The main goal of development is to improve their versatility in terms of lifetime, durability, efficiency, and extended temperature range. Recent investigations and developments include the use of alternative materials for oven components. The main focus has been on the further development of the high temperature oven. A modular construction with improved mechanical dimensional accuracy for more precise and easier mounting has been established. Its optimization for stable long time operation has been continued leading to a lifetime of 6 days for evaporation of Ti at 1750°C. Furthermore the temperature limit could be extended to 2300°C. In addition to the improvements in evaporation technology the technique of microwave frequency tuning could be successfully applied for metal ion operation leading to enhanced ion beam intensities.  
 
WEPP16 Experimental Studies on the ALISES Ion Source at CEA Saclay plasma, ion, electron, extraction 143
 
  • O. Tuske, O. Delferrière, Y. Gauthier, R. Gobin, F. Harrault, J.L. Jannin
    CEA/DSM/IRFU, France
  • S. Nyckees
    CEA/IRFU, Gif-sur-Yvette, France
 
  The ALISES ion source was originally designed to reduce beam emittance at RFQ entrance by shortened the length of the LEBT. A wide opened magnetic coil at ground potential produces the fringe field needed for the ECR heating at 2.45 GHz frequency. The first part describes the commissioning of the source: Penning discharges inside the accelerating column make the high voltage power supply collapse. Experimental tests with kapton films while discharges occur, and simulations with OPERA-3D code have shown great similarities to detect the location of those discharges and allow us to make the ion source work. The second part of this paper will present the result of low intensity light ion beam production versus the plasma chamber length and radius. Those very preliminary tests give us indications to reduce the ion source dimensions.  
poster icon Poster WEPP16 [2.556 MB]  
 
WEPP17 A Multi-Sample Changer Coupled to an ECR Source for AMS Experiments plasma, laser, ion, ECR 146
 
  • R.C. Vondrasek, T. Palchan, R.C. Pardo, C.E. Peters, M.A. Power, R.H. Scott
    ANL, Argonne, USA
 
  Funding: This work was supported by the U.S. Department of Energy, Office of Nuclear Physics, under Contract No. DE-AC02-06CH11357.
A project using Accelerator Mass Spectrometry (AMS) at the ATLAS facility to measure neutron capture rates on a wide range of actinides in a reactor environment is underway. This project will require the measurement of a large number of samples previously irradiated in the Advanced Test Reactor at Idaho National Laboratory. The AMS technique at ATLAS is based on production of highly-charged positive ions in an electron cyclotron resonance ion source (ECRIS) followed by acceleration in the ATLAS linac. The sample material is introduced into the plasma via laser ablation. This should limit the dependency of material feed rates upon the source material composition as well as minimize cross-talk between samples. A new multi-sample changer has been constructed allowing rapid changes between samples. The sample changer has 20 positions and is capable of moving from one sample to the next in one minute. Details of the sample changer design and operation will be presented.
 
 
THXO02 Current Developments of the VENUS Ion Source in Research and Operations plasma, ion, extraction, cyclotron 153
 
  • J.Y. Benitez, K.Y. Franzen, C.M. Lyneis, L. Phair, M.M. Strohmeier
    LBNL, Berkeley, California, USA
  • G. Machicoane
    FRIB, East Lansing, Michigan, USA
  • L.T. Sun
    IMP, Lanzhou, People's Republic of China
 
  The VENUS ion source functions as a research and development tool in the ECR community as well as an injector for LBNL's 88-Inch cyclotron. In order to meet the needs of both the ECR community and users at the 88-Inch cyclotron, technology such as ovens and a sputter probe have been developed for introducing metals into the plasma. Using a modified high temperature oven, VENUS has produced 450 eμA of 238U33+ and 400 eμA of 238U34+, twice the required Uranium beam current needed for FRIB. In addition, after upgrading its high voltage capabilities VENUS produced 11emA of 4He2+, a capability that remains unparalleled by other ECR ion sources. In addition to its recent record high intensities VENUS is also being developed to deliver low intensity, ultra high charge state ions for the cocktails beams, where many species are produced simultaneously for use by the BASE Facility. 124Xe43+ is now in regular production for the 16 MeV/u cocktail, and development of 209Bi56+ for the 10 MeV/u cocktail is in progress and has been accelerated through the 88-Inch cyclotron. This paper presents the latest work towards integrating the VENUS ion source into our research and operational goals.  
slides icon Slides THXO02 [8.391 MB]  
 
THXO03 Recent RIKEN 28 GHz SC-ECRIS Results ion, ECRIS, extraction, ECR 159
 
  • Y. Higurashi, M. Fujimaki, H. Haba, O. Kamigaito, M. Kidera, M. Komiyama, J. Ohnishi, K. Ozeki
    RIKEN Nishina Center, Wako, Japan
  • T. Aihara, M. Tamura, A. Uchiyama
    SHI Accelerator Service Ltd., Tokyo, Japan
 
  For increasing the beam intensity of highly charged heavy ions at RIKEN RIBF, we constructed new SC-ECR ion source. In the spring of 2011, we injected 28GHz microwave into the ion source and obtained first beam. Since then, we made several test experiments for increasing the beam intensity of highly charged Xe and U ion beam, and produced ~60 eμA of U35+, ~90 eμA of U33+ at the injected RF power of ~2 kW using sputtering method. In case of Xe25+, 250 euA was obtained at RF power of 1.7 kW. Using sputtering method, we produced U35+ ion beam longer than one month for the RIBF experiment without break. In the beginning of 2012, we installed additional GM-JT refrigerator to increase the cooling power at 4.2 K, then the total cooling power became higher than 9 W. Using it, we can use higher than 8 W of cooling power for heat load due to the absorbed X-rays. In this summer, we will install the new plasma chamber made of Al for increasing the cooling power. We will also use high temperature oven to increase the U vapor. In this contribution, we report the recent modification of the ion source and test experiments for production of U and Xe ion beam.  
slides icon Slides THXO03 [49.487 MB]  
 
THYO03 Design Status of ECR Ion Sources and LEBT for FRIB ion, ECR, sextupole, solenoid 172
 
  • G. Machicoane, N.K. Bultman, G. Morgan, E. Pozdeyev, X. Rao
    FRIB, East Lansing, Michigan, USA
  • J.Y. Benitez, C.M. Lyneis
    LBNL, Berkeley, California, USA
  • L.T. Sun
    IMP, Lanzhou, People's Republic of China
 
  Funding: Work supported by the U.S. Department of Energy Office of Science under Cooperative Agreement DE-SC0000661
The Facility for Rare Isotope Beams at Michigan State University is currently being designed and will provide intense beams of rare isotopes for research in nuclear physics, nuclear astrophysics and study of fundamental interactions. The FRIB driver linac will accelerate all stable isotopes from Oxygen to Uranium to energies beyond 200 MeV/u at beam powers up to 400 kW. In the case of Uranium about 13.3 pμA of U33+ are required from the ion source to reach the maximum beam power on the target. Such current is at the limit of what an ECR ion source can produce and led us to design the FRIB driver linac to accelerate concurrently two charges. The ECR ion source for FRIB will be based on the VENUS ion source developed at Lawrence Berkeley National Laboratory (LBNL). Recent beam measurements done with VENUS have demonstrated that the ion source can actually produce close to 13pμA of U33+ and therefore could possibly meet the current required for FRIB in one charge state. This paper reviews the status of the FRIB ECR ion source and the modifications that have been made to the VENUS ion source design. The Low energy beam line transport (LEBT) will also be presented and discussed.
 
slides icon Slides THYO03 [6.532 MB]  
 
THYO04 Performance of the ANL ECR Charge Breeder with Low Mass Beams ion, plasma, injection, ECR 177
 
  • R.C. Vondrasek, S.V. Kutsaev, R.C. Pardo, R.H. Scott
    ANL, Argonne, USA
  • P. Delahaye, L. Maunoury
    GANIL, Caen, France
 
  Funding: This work was supported by the U.S. Department of Energy, Office of Nuclear Physics, under Contract No. DE-AC02-06CH11357.
The Californium Rare Ion Breeder Upgrade (CARIBU) of the ATLAS superconducting linac facility aims at providing low-energy and reaccelerated neutron-rich radioactive beams to address key nuclear physics and astrophysics questions. These beams are obtained from fission fragments of a Cf-252 source, thermalized and collected into a low-energy particle beam by a helium gas catcher, mass analyzed by an isobar separator, and charge bred with an ECR ion source for acceleration in ATLAS. The charge breeding program had focused on optimizing beams in the mid-mass range, achieving high charge breeding efficiencies of both gaseous and solid species including 14.7% for the radioactive species 143Ba27+. In an effort to better understand the charge breeding mechanism, we recently focused on the low-mass species sodium and potassium which up to present have been difficult to charge breed efficiently. Charge breeding efficiencies of 10.1% for 23Na7+ and 17.9% for 39K10+ were obtained injecting stable Na+ and K+ beams from a surface ionization source. Details of these studies will be presented as well as simulations detailing the injection of the low charge state beams into the charge breeder.
 
slides icon Slides THYO04 [9.178 MB]  
 
FRXA02 All Permanent Magnet ECR Ion Source Development and Operation Status at IMP ion, ECR, plasma, permanent-magnet 185
 
  • L.T. Sun, Y. Cao, J.Q. Li, J.Y. Li, B.H. Ma, H. Wang, J.W. Xia, D. Xie, W.H. Zhang, X.Z. Zhang, H.W. Zhao
    IMP, Lanzhou, People's Republic of China
 
  All permanent magnet ECR ion sources have many advantages over traditional ECR ion sources composed of several axial room temperature solenoids and one permanent magnet hexapole magnet, which make them the first choice for many heavy ion facilities and platforms. At IMP, three types of all permanent magnet ECR ion sources have been built for different applications, i.e. the very compact ECR ion source LAPECR1 for intense mono or multi charge state ion beam production, the LAPECR2 ion source installed on the 320 kV high voltage multidisciplinary platform, and the LAPECR3 ion source dedicated to C5+ beam production for the cancer therapy facility. In this paper, after a general discussion of the ion sources' design, the applications and the operation status of the IMP all permanent magnet ECR ion sources will be presented.  
slides icon Slides FRXA02 [6.380 MB]  
 
FRYA01 ECRISs at GANIL Today and Tomorrow ion, ECRIS, target, ECR 195
 
  • P. Jardin, O. Bajeat, C. Barue, C. Canet, P. Delahaye, M. Dubois, M. Dupuis, J.L. Flambard, R. Frigot, C. Leboucher, P. Lehérissier, F. Lemagnen, L. Maunoury, O. Osmond, J. Piot, E.K. Traykov
    GANIL, Caen, France
  • B.J.P. Gall
    IPHC, Strasbourg Cedex 2, France
  • C. Peaucelle
    IN2P3 IPNL, Villeurbanne, France
  • J. Rubert, T. Thuillier
    LPSC, Grenoble Cedex, France
  • O. Tuske
    CEA/DSM/IRFU, France
 
  GANIL (Grand accélérateur National d'Ions Lourds) uses ECRIS for producing stable and radioactive ions since more than 20 years. 2 ECR4 type IS deliver intense multi-charged stable ion beams of gaseous and metallic elements to cyclotrons for post acceleration to energies up to 100 A·MeV. A full permanent magnet ECRIS is also used for producing multi-charged radioactive ion beams in the frame of SPIRAL 1 (Système de Production d'Ions radioactifs Accélérés en Ligne, part 1). For atomic physic experiment, a high performance ECRIS named GTS developed at CENG/ Grenoble (France) is currently used to deliver high intensity, high charge state and low energy ion beams. To extend the range of radioactive ion beams available at GANIL, two ISOL (Isotope Separator On Line) projects are underway (SPIRAL2 and SPIRAL1 upgrade). In the frame of these projects, radiation hard singly-charged ECRIS, Q/A=1/3 ECRIS, 2.45 GHz deuteron ECRIS and permanent magnet TISS (Target Ion Source System) using an ECRIS are in development in parallel. A review of the main uses, current developments and performances obtained or expected with ECRISs at GANIL will be presented.  
slides icon Slides FRYA01 [6.926 MB]  
 
FRYA02 Status of ECR Ion Sources for Carbon-ion Radiotherapy in Japan ion, ECR, operation, extraction 200
 
  • A. Kitagawa, M. Muramatsu
    NIRS, Chiba-shi, Japan
  • A.G. Drentje
    KVI, Groningen, The Netherlands
  • T.F. Fujita
    National Institute of Radiological Sciences, Chiba, Japan
  • M. Kanazawa
    SAGA HIMAT, Saga, Japan
  • N. Sasaki, W. Takasugi
    AEC, Chiba, Japan
  • E. Takeshita, S. Yamada
    Gunma University, Heavy-Ion Medical Research Center, Maebashi-Gunma, Japan
 
  Heavy-ion radiotherapy is successfully carried out at the Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences (NIRS) since 1994. Now three facilities are in operation and two are under construction in Japan. Over 8000 cancer patients have already been treated. 140-400 MeV/u carbon beams were selected for the first clinical trials at HIMAC because carbon is one of the best candidates which gives good localized biological dose distribution for the typical conditions, a depth of 10 - 25 cm and a thickness of several cm. Based on the clinical results, all the patients have been treated by carbon beams at present. The ion source needs to realize a stable carbon beam with the same conditions for daily operation. Since operators are usually not specialists of the ion source, the source should not require complicated manual tuning. In addition, shorter maintenance time and cycle are better for a hospital. ECR ion sources are utilized for such requirements in each facility. We report the recent status of the ECR ion sources at heavy-ion radiotherapy facilities in Japan.  
slides icon Slides FRYA02 [5.652 MB]  
 
FRYA03 ECRIS Related Research and Development Work at JYFL and Some Future Prospects ion, plasma, photon, electron 203
 
  • H. A. Koivisto, J. Ärje, T. Kalvas, J.P.O. Komppula, R.J. Kronholm, J.P. Laulainen, O.A. Tarvainen, V. Toivanen
    JYFL, Jyväskylä, Finland
 
  Since the last ECR workshop the JYFL ion source group has focused on the plasma research, work on the ion beam formation and transport and development of metal ion beams. The plasma research can be divided into plasma breakdown processes, plasma and ion beam instabilities and afterglow processes. The afterglow and instability experiments will be presented elsewhere in these proceedings [1]. In addition, studies involving in the photoelectric induced electron emission and charge exchange reactions will be briefly discussed and the experiments concerning the resonance properties of empty and plasma loaded cavity will be presented. An improvement in ion beam transport of the JYFL K130 cyclotron facility was achieved as a result of the work performed on ion beam formation. This work will be described in more detailed elsewhere in these proceedings [2]. The MIVOC method and sputtering technique were further studied in order to produce intensive titanium ion beams. As a result, an intensive {50}Ti ion beam was successfully produced with the MIVOC method and interesting behavior regarding the sputtering was noticed.
[1] V. Skalyga et al. and O. Tarvainen et al.
[2] V. Toivanen et al.
 
slides icon Slides FRYA03 [4.159 MB]