WEPAG004 |
Automating Orbit Correction in the Main Injector 8 GeV Line |
controls, dipole, booster, operation |
2070 |
|
- K.J. Hazelwood, I. Kourbanis, G.E. Krafczyk, M.-J. Yang
Fermilab, Batavia, Illinois, USA
|
|
|
The Main Injector 8 GeV line (MI8 line) transports beam from Fermilab's Booster accelerator to either the Booster Neutrino experiments (BNB), the Recycler or the Main Injector. Often the orbit of the beam through the MI8 line differs depending on the beam destination. The beam is collimated in the MI8 line, so increasing intensities and repetition rates make controlling orbits through the collimators a necessity. The current method of regulating the MI8 line orbit with DC corrector settings is insufficient. A system named MITUNE is being developed to sample and categorize all beams through the MI8 line and automatically calculate and apply proper dipole corrector ramps to maintain desired orbits for pulses to any destination.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAG004
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
WEPAK016 |
RF Monitor System for SuperKEKB Injector Linac |
linac, FPGA, controls, EPICS |
2128 |
|
- H. Katagiri, M. Akemoto, D.A. Arakawa, T. Matsumoto, T. Miura, F. Qiu, Y. Yano
KEK, Ibaraki, Japan
|
|
|
A new radio frequency (RF) monitor system for the SuperKEKB project has been developed at the KEK in-jector linac. The RF monitor unit, which consists of an analog I/Q demodulator, ADC/DAC board, and FPGA board achieved 50-Hz data acquisition and beam mode identification. On the RF monitor, the amplitude and phase measurement precision has achieved 0.1% rms and 0.1° rms, respectively. Sixty RF monitor units have been installed in the linac. The present status of the RF monitor system will be re-ported.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAK016
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPAL051 |
The Data Acquisition on Vibration Evaluation for Ice Water Pumps Systems in TPS |
status, synchrotron, operation, controls |
3757 |
|
- Y.-H. Liu, C.-S. Chen, Y.-C. Chung, Z.-D. Tsai
NSRRC, Hsinchu, Taiwan
|
|
|
The vibration status is a critical problem for the utility system, especially for those continuously operate deionized and cooling water pumps used in synchrotron accelerator. The purpose of this paper is to evaluate the vibration level and spectrum condition for TPS water pump systems. In order to predictive maintenance before pump systems fail, the vibration monitoring system was constructed. After vibration test for several months, the alignment of some of the ice water pumps were found mismatched because of poor system positioning and operate continuously. Besides, the ice water pump were redundantly operated and switch over every Monday morning. The recorded data showed the system sometimes switch fail because of control status or system stability. Thus, the water pump systems were repaired and maintained base on vibration monitoring system. There is still some remain problems for ice water pump systems. The utility systems could prevent malfunction through regular vibration inspection and daily data acquisition.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-THPAL051
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPML069 |
The Control System Design of SCLF |
controls, interface, network, software |
4800 |
|
- Y.B. Yan, J.G. Ding, G.Y. Jiang, Y.B. Leng
SSRF, Shanghai, People's Republic of China
- J.F. Chen
SINAP, Shanghai, People's Republic of China
|
|
|
The high-gain free electron lasers have given scientists hopes for new scientific discoveries in many frontier research areas. The Shanghai Coherent Light Facility (SCLF) was proposed by the central government of China on April 2017, which is a quasi-continuous wave hard X-ray free electron laser facility. The control system is responsible for the facility-wide device control, data acquisition, machine protection, high level database or application, as well as network and computing platform. It will be mainly based on EPICS to reach the balance between the high performance and costs of maintenance. The latest technology will be adopted for the high repetition rate data acquisition and feedback system. The details of the control system design will be reported in this paper.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2018-THPML069
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|