Keyword: acceleration
Paper Title Other Keywords Page
MOPE02 Studies on Flow-Induced Vibrations for the New High-Dynamics DCM for Sirius ion, experiment, controls, synchrotron 8
 
  • R.M. Caliari, O.R. Bagnato, F.R. Francisco, R.R. Geraldes, R.L. Parise, M. Saveri Silva, D.O. Tavares, L.,Jr. de Souza
    LNLS, Campinas, Brazil
  • T.A.M. Ruijl
    MI-Partners, Eindhoven, The Netherlands
 
  The monochromator is known to be one of the most critical optical elements of a synchrotron beamline, since it directly affects the beam quality with respect to energy and position. Naturally, the new 4th generation machines, with their small emittances, start to bring about higher stability performance requirements, in spite of factors as high power loads, power load variation, and vibration sources. A new high-dynamics DCM (Double Crystal Monochromator) is under development at the Brazilian Light Source for the Sirius EMA beamline (Extreme Condition X-ray Methods of Analysis). The disturbances induced by the coolant flows are known to be among the most detrimental influences to a DCM performance, however, quantitative force numbers involved in such disturbances are not commonly investigated. According to the novel dynamic concept, these forces should be predictably translated into stability performance. Therefore, experimental setups that allow the indirect measurement of such forces in conditions close to those of operation were designed. The results comparing different indirect cooling profiles and manufacturing processes (brazing and additive manufacturing) are shown.  
poster icon Poster MOPE02 [3.064 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2016-MOPE02  
About • paper received ※ 09 September 2016       paper accepted ※ 15 September 2016       issue date ※ 22 June 2017  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUCA02 Structural Dynamic Modelling and Measurement of SwissFEL Bunch Compressor ion, GUI, FEL, damping 128
 
  • X. Wang, H. Jöhri, F. Löhl, M. Pedrozzi, T. Stapf
    PSI, Villigen PSI, Switzerland
 
  Magnetic chicanes are used in accelerator facilities to longitudinally compress the accelerated particle bunches. The second compression chicane (BC2) of SwissFEL consists of four dipole magnets bending the beam on the horizontal plane along a C-shaped orbit and has a total length of 17 m. The position of the two central dipoles can be continuously adjusted to achieve the required transverse offset in order to realize a wide range of compression schemes. To ensure the requires mechanical stability of the accelerator components sitting on the long and movable steel girder (7.7 m), it is essential to design a stiff support structure with high eigen frequencies. In the design stage, displacement frequency responses are calculated in a modal based linear dynamic analysis using finite element method to ensure vibration amplitude below 1 micrometer. Special considerations are given to the modelling of linear guide systems, as they introduce nonlinear support conditions and need to be adequately simplified in the calculation. After completing the BC2 assembly, vibration measurements were performed. Finally, the validation of the numerical model by measurement results will be presented.  
slides icon Slides TUCA02 [3.884 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2016-TUCA02  
About • paper received ※ 10 September 2016       paper accepted ※ 20 September 2016       issue date ※ 22 June 2017  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)