Keyword: permanent-magnet
Paper Title Other Keywords Page
TUPH03 U15 Design and Construction Progress undulator, vacuum, cryogenics, operation 26
 
  • F. Briquez, C.A. Arrachart, N.B. Baron, P. Berteaud, F. Blache, C.B. Bourgoin, N. Béchu, M.-E. Couprie, J. Da Silva Castro, J.M. Dubuisson, J.P. Duval, C. Herbeaux, F. Lepage, A. Lestrade, F. Marteau, A. Mary, F.M. Michel, S.M. Morand, M.-H. Nguyen, A.R. Rouquié, M. Sebdaoui, G. Sharma, K.T. Tavakoli, M. Tilmont, M. Valléau, M.V. Vandenberghe, J. Vétéran, C. de Oliveira
    SOLEIL, Gif-sur-Yvette, France
 
  A 15 mm period PrFeB Cryogenic Permanent Magnet Undulator (CPMU) is under construction at SOLEIL in the frame of a collaboration with MAXIV, relying on the experience gained from the two PrFeB CPMU already installed at SOLEIL. The improved design includes a magnetic length of 3 m and a minimum gap of 3 mm, leading to a polyvalent device of interest for both synchrotron radiation sources and free electron lasers. A dedicated magnetic measurement bench is also under development to perform measurements at cryogenic temperature, based on the SAFALI system. The designs of both undulator and measurement bench will be explained, the construction progress will be detailed and first results will be given.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH03  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPH19 A Mechanical Undulator Frame to Minimize Intrinsic Phase Errors vacuum, operation, undulator, GUI 69
 
  • J.C. Huang, C.H. Chang, C.-S. Hwang, C.S. Yang, C.K. Yang
    NSRRC, Hsinchu, Taiwan
  • H. Kitamura
    RIKEN SPring-8 Center, Sayo-cho, Sayo-gun, Hyogo, Japan
  • S. M. Mizumoto
    NEOMAX Co., Ltd., Mishima-gun, Osaka, Japan
 
  A PrFeB-based cryogenic permanent magnet undu-lator (CPMU) is under construction at the Taiwan Photon Source (TPS) to generate brilliant X-rays. When magnets are cooled to 77 K, a CPMU with a period length of 15 mm can generate an effective magnetic field of 1.32 T in a gap of 4 mm. A main feature of the TPS CPMU is its low-intrinsic-phase errors by the installation of force-compensation modules on the out-of-vacuum girders in a four-support-points configuration. Moreover, adjusting the spring settings one can obtain very low undulator phase errors. In this paper, a mechanical frame design for the TPS-CPMU with force-compensating spring modules will be discussed. Observations of deformation effects of the out-of-vacuum girders on the CPMU will be presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH19  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPH37 MAGSTAT V3: An In-Vacuum Variable-Gap Quadrupole with Rotary Permanent Magnets quadrupole, vacuum, GUI, synchrotron 412
 
  • V. Pinty, N. Jaouen, F. Marteau, H. Popescu, P. Prout
    SOLEIL, Gif-sur-Yvette, France
 
  MAGSTAT is a quadrupole designed to magnetize samples with a variable magnetic field in flow density and in directions. Four rotary permanent magnets allow the user to specify a direction for the field and changing in situ the gap between the poles drives the field intensity. The first prototype was realized in 2016 on the SEXTANTS beamline in the framework of SOLEIL-MAXIV collaboration; a second version has been manufactured for MAXIV SoftImax beamline. This third version shows a significant evolution of the mechanical design, guaranteeing a much better stiffness in high field configurations. Samples up to Ø74mm can be placed in this quadrupole, and the tiny ones which may fit in a Ø10mm circle or smaller, can be magnetized with a 1T local field. The angle of each magnet is driven by a dedicated stepper motors with a big reduction ratio. The total gap is ensured by a single motor, and its motion is symmetrically transferred to the magnets through an Archimedean spiral. The first prototype is installed at COMET endstation dedicated to the coherent scattering of soft X-ray in transmission for imaging magnetic materials via the Fourier Transform Holography or ptychography techniques.  
poster icon Poster THPH37 [57.424 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-THPH37  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)