Author: Zhang, X.Z.
Paper Title Page
TUPP13 Development of Intense Proton ECR Ion Sources at IMP 64
 
  • Z.M. Zhang, Z.W. Liu, H.Y. Ma, L.T. Sun, Q. Wu, Y. Yang, W.H. Zhang, X.Z. Zhang, H.W. Zhao
    IMP, Lanzhou, People's Republic of China
 
  Since 1997, there have been two ECR ion sources for producing intense proton beam developed at Institute of Modern Physics (IMP). In 1999, a high current 2.45 GHz ECR proton source for Lanzhou university neutron generator, was constructed and tested at IMP. A mixed ion (H1+ + H2+ + H3+) beam current of 110 mA with CW mode was delivered from a single aperture of 6mm diameter with microwave power of 600 W at the extraction voltage of 22 kV. Recently a new pulsed proton source has been designed and built at IMP for the CPHS (Compact Pulse Hadron Source) facility in Tsinghua University. Now this source is under commissioning for 60 mA proton beam with 50 keV energy. The long time running stability and beam emittance have been tested and the results are well up to the requirements of CPHS. In this paper, after a short review of the proton ion source for Lanzhou University, the design and test results of the CPHS proton source as well as the LEBT will be presented. The design of the proton ion source and the LEBT for the Chinese ADS project will also be discussed in the contents.  
 
WEPP13 Development Update of the LECR4 Ion Source - Dragon at IMP 133
 
  • W. Lu, B.H. Ma, L.T. Sun, H. Wang, D. Xie, X.Z. Zhang, H.W. Zhao
    IMP, Lanzhou, People's Republic of China
  • L. Ruan, B. Xiong
    IEE, Beijing, People's Republic of China
 
  A new room temperature ECR ion source, LECR4-DRAGON to operate at 18 GHz, is under development for the SSC-LINAC project at IMP. In comparison to other room temperature ECRISs, one unique feature of LECR4-DRAGON is that its plasma chamber is of ID 126 mm that is the biggest chamber for a room temperature ECRIS and the same as the superconducting ECR ion source SECRAL. Because the project funding requests testing a different magnet cooling scheme, solid quadrate copper coils cooled by medium evaporation at about 50oC are to be used to produce a maximum axial magnetic field of about 2.5 T at injection and 1.4 T at the extraction, which are similar to SECRAL operating at 18 GHz. Furthermore, a large bore non-Halbach permanent sextupole with staggered structure has been under fabrication which can produce a radial magnetic field reaching 1.5 T at the plasma chamber wall for operation at 18 GHz. The progress updates and discussions of this new ion source will be presented in this paper.  
 
THXO01 Optimization of the New SC Magnetic Structure Design with a Hybrid Magnet 149
 
  • D. Xie, W. Lu, L.Z. Ma, L.T. Sun, X.Z. Zhang, H.W. Zhao, L. Zhu
    IMP, Lanzhou, People's Republic of China
 
  In the development of the next generation ECRISs, so far either a set of full NbTi or full Nb3Sn magnets has been proposed to construct the magnet system. However, the single set of magnets may not be the optimum in terms of the field strength and configuration. An optimization of the new SC magnetic structure with a set of hybrid magnets (NbTi and Nb3Sn) is being investigated. With the hybrid magnet the optimized new magnetic system is capable of producing field maxima of 9.0 T on axis and 4.0 T at the plasma wall, which are 30 and 10% higher than the previously proposed magnetic structure to be built with a set of full NbTi magnets. In addition, the axial length of the optimized magnetic structure has been slightly shrunk resulting in a more compact system. This new magnetic field profile is high enough for operation frequency up to 56 GHz. The design features and the preliminary force/stress analyses of the optimized new SC magnetic structure will be presented and discussed.  
slides icon Slides THXO01 [2.603 MB]  
 
THXO04
SECRAL status and future challenge  
 
  • H.W. Zhao, W. Lu, L.T. Sun, D. Xie, X.Z. Zhang
    IMP, Lanzhou, People's Republic of China
 
  SECRAL, the superconducting ECR ion source at IMP, has been in routine operation for the HIRFL accelerator complex since May 2007. The total operation beam time provided by SECRAL has so far exceeded 9500 hours. In most cases SECRAL has been operating at 18 GHz for the accelerator complex, and only operating at 24 GHz for the very high charge states and very heavy ion beams such as Bi and U beams. Uranium beam was tested at 24 GHz with ion sputtering in which 160 eμA of 238U33+ was produced, and 238U32+ beam was delivered to the accelerator continuously for almost one month. Beam long-term stability and emittance at high rf power of 24 GHz were studied. The operation status and the latest performance of SECRAL ion source will be presented. A new heavy ion accelerator facility HIAF has been proposed at IMP. HIAF requests an ion source capable of producing a pulse beam of 2.0 emA of 238U34+. A next generation superconducting ECR ion source with operating frequency up to 50-60 GHz is under consideration in which a few options for the superconducting magnet configuration are being studied. Technical challenges for the next generation ECR ion source will be reviewed.  
slides icon Slides THXO04 [12.086 MB]  
 
FRXA02 All Permanent Magnet ECR Ion Source Development and Operation Status at IMP 185
 
  • L.T. Sun, Y. Cao, J.Q. Li, J.Y. Li, B.H. Ma, H. Wang, J.W. Xia, D. Xie, W.H. Zhang, X.Z. Zhang, H.W. Zhao
    IMP, Lanzhou, People's Republic of China
 
  All permanent magnet ECR ion sources have many advantages over traditional ECR ion sources composed of several axial room temperature solenoids and one permanent magnet hexapole magnet, which make them the first choice for many heavy ion facilities and platforms. At IMP, three types of all permanent magnet ECR ion sources have been built for different applications, i.e. the very compact ECR ion source LAPECR1 for intense mono or multi charge state ion beam production, the LAPECR2 ion source installed on the 320 kV high voltage multidisciplinary platform, and the LAPECR3 ion source dedicated to C5+ beam production for the cancer therapy facility. In this paper, after a general discussion of the ion sources' design, the applications and the operation status of the IMP all permanent magnet ECR ion sources will be presented.  
slides icon Slides FRXA02 [6.380 MB]