Keyword: ISOL
Paper Title Other Keywords Page
THP22 Guaranteeing the Measurement Accuracy in Em#* impedance, target, synchrotron, FPGA 216
 
  • X. Serra-Gallifa, J.A. Avila-Abellan, M. Broseta, G. Cuní, O. Matilla
    ALBA-CELLS Synchrotron, Cerdanyola del Vallès, Spain
 
  ALBA, in collaboration with MAXIV, has developed a four-channel electrometer of 18bit deep with 8 ranges from 1mA to 100pA. The objective of accuracy in the measurements made clear from the beginning the need to compensate the components tolerances and its dependence with temperature. This paper describes the tests performed to characterize the acquisition chain, the automatic calibration developed and the hardware and software implemented to achieve the accuracy target. This implementation has been eased due to the high flexibility given by ALIN and Harmony** architectures used in the Em#.
* J.Avila-Abellan, "Em# Electrometer Comes to Light", ICALEPCS’17.
** M.Broseta, "Present and Future of Harmony Bus, a real-time high speed bus for data transfer between FPGA cores", ICALEPCS’17.
 
poster icon Poster THP22 [1.037 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-PCaPAC2018-THP22  
About • paper received ※ 10 October 2018       paper accepted ※ 16 October 2018       issue date ※ 21 January 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)