Keyword: power-supply
Paper Title Other Keywords Page
WEPH29 NSLS-II Vibration Studies to Characterize Beamline Stability experiment, operation, detector, ion-source 267
 
  • C.J. Spataro, F.C. Lincoln, S.K. Sharma
    BNL, Upton, Long Island, New York, USA
 
  High per­for­mance goals of NSLS-II re­quire strin­gent me­chan­i­cal sta­bil­ity of its in­stru­ments such as BPMs, slits, mir­rors, mono­chro­ma­tors, and de­tec­tors. Me­chan­i­cal sta­bil­ity of these com­po­nents can be com­pro­mised by site-wide as well as local vi­bra­tion sources (pumps, com­pres­sors, etc.). Sev­eral vi­bra­tion stud­ies have been per­formed at NSLS-II at the re­quest of beam­line users. This paper pre­sents the re­sults of these stud­ies high­light­ing sources of vi­bra­tion and mit­i­ga­tion strate­gies.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-WEPH29  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)