Author: Ramanathan, M.
Paper Title Page
WEPE04 Design of X-Ray Beam Position Monitor for High Heat Load Front Ends of the Advanced Photon Source Upgrade 318
 
  • S.H. Lee, J. Mulvey, M. Ramanathan, B.X. Yang
    ANL, Argonne, Illinois, USA
 
  Funding: Work supported by the U.S. Department of Energy, Office of Science, under Contract No. DE-AC02-06CH11357
Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source (APS). Currently, the APS is upgrading its facility to increase productivity and to provide far more highly coherent and brilliant hard x-rays to beamline experiments with a new storage ring magnet lattice based on a multi-bend achromat (MBA) lattice. To improve the beam stability, one of the proposed beam diagnostics is the grazing-incidence insertion device x-ray beam position monitor (GRID-XBPM) for high heat load (HHL) front ends (FEs) at the APS. In this paper, final design of the GRID-XBPM and the high-power beam test results at beamline 27-ID-FE will be addressed.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2016-WEPE04  
About • paper received ※ 07 September 2016       paper accepted ※ 21 September 2016       issue date ※ 22 June 2017  