TY - CONF AU - Lee, S.H. AU - Mulvey, J. AU - Ramanathan, M. AU - Yang, B.X. ED - Casas, Joan ED - Schaa, Volker RW ED - Costa, Isidre ED - López, David ED - Prieto, Montserrat TI - Design of X-Ray Beam Position Monitor for High Heat Load Front Ends of the Advanced Photon Source Upgrade J2 - Proc. of MEDSI2016, Barcelona, Spain, 11-16 September 2016 CY - Barcelona, Spain T2 - Mechanical Engineering Design of Synchrotron Radiation Equipment and Instrumentation Conference T3 - 9 LA - english AB - Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source (APS). Currently, the APS is upgrading its facility to increase productivity and to provide far more highly coherent and brilliant hard x-rays to beamline experiments with a new storage ring magnet lattice based on a multi-bend achromat (MBA) lattice. To improve the beam stability, one of the proposed beam diagnostics is the grazing-incidence insertion device x-ray beam position monitor (GRID-XBPM) for high heat load (HHL) front ends (FEs) at the APS. In this paper, final design of the GRID-XBPM and the high-power beam test results at beamline 27-ID-FE will be addressed. PB - JACoW Publishing CP - Geneva, Switzerland SP - 318 EP - 320 KW - ion KW - detector KW - vacuum KW - radiation KW - undulator DA - 2017/06 PY - 2017 SN - 978-3-95450-188-5 DO - doi:10.18429/JACoW-MEDSI2016-WEPE04 UR - http://jacow.org/medsi2016/papers/wepe04.pdf ER -