Keyword: beam-transport
Paper Title Other Keywords Page
TUPAF077 Beam Optics Measurements in Medium Energy Beam Transport at PIP-II Injector Test Facility quadrupole, optics, rfq, emittance 909
 
  • A. Saini, J.-P. Carneiro, B.M. Hanna, L.R. Prost, A.V. Shemyakin
    Fermilab, Batavia, Illinois, USA
  • V.L. Sista
    BARC, Mumbai, India
 
  Funding: This manuscript has been authored by Fermi Research Alliance, LLC under Contract No. DE-AC02-07CH11359 with the U.S. Department of Energy, Office of Science, Office of High Energy Physics
The Proton Improvement Plan-II Injector Test (PIP2IT) is an accelerator test facility under construction at Fermilab that will provide a platform to demonstrate critical technologies and concept of the front-end of the PIP-II linear accelerator (linac). The PIP2IT warm front-end comprises a H ion source capable of delivering 15 mA, 30 keV DC or pulsed beam, a Low Energy Beam Transport (LEBT), a 162.5 MHz, CW Radio Frequency Quadrupole (RFQ) that accelerates the beam to 2.1 MeV and, a 14 m medium energy beam transport (MEBT). Presently, beamline up to the MEBT has been commissioned and operates routinely at the PIP2IT facility. In this paper, we discuss beam measurements performed at the MEBT to analyze beam emittance and its RMS sizes along the MEBT. In addition, beam based calibration of the beamline elements using differential trajectory measurement is also presented.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPAF077  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPAL025 Preliminary Test of the Beam Transport System for Li-8 Production Target Ion Source target, proton, ion-source, neutron 1054
 
  • H.-J. Kwon, Y.-S. Cho, J.J. Dang, D.I. Kim, H.S. Kim, S. Lee, Y.G. Song, S.P. Yun
    Korea Atomic Energy Research Institute (KAERI), Gyeongbuk, Republic of Korea
 
  Funding: This work has been supported by through KOMAC (Korea Multi-purpose Accelerator Complex) operation fund of KAERI by MSIT (Ministry of Science and ICT)
A prototype target ion source was developed in order to produce a radioactive beam such as Li-8 as a part of the goals to establish a platform for secondary particle production at KOMAC (Korea Multi-purpose Accelerator Complex). A beam transport system from the 100-MeV linac to prototype target ion source was designed and constructed. It consists of 8 quadrupole magnets, 2 bending magnets and beam diagnostic devices such as AC current transformers, beam position monitors, beam profile monitors and beam loss monitors. Details on the beam transport system and test results are presented.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPAL025  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPAL044 Technical Workings of the 6D Phase Measurement at SNS dipole, electron, diagnostics, data-analysis 1107
 
  • B.L. Cathey
    ORNL RAD, Oak Ridge, Tennessee, USA
  • A.V. Aleksandrov, S.M. Cousineau, A.P. Zhukov
    ORNL, Oak Ridge, Tennessee, USA
 
  Funding: SNS is managed by UT-Battelle, LLC, under contract DE-AC05-00OR22725 for the U.S. Department of Energy. This work has been partially supported by NSF Accelerator Science grant 1535312.
The Beam Test Facility (BTF) is a functional duplicate of the Spallation Neutron Source (SNS) frontend with a 2.5 MeV beam on which the first six-dimensional phase space measurement has been completed. This presentation will show the technical underpinnings involved in performing the 6D scan with the BTF. The first part will examine the diagnostic setup involving apertures, a screen, and a bunch shape monitor and how the integrated system functions. The next part will cover the scan logic used in the software. The last part will briefly discuss ongoing efforts to analyze 6D measurements and identify correlations.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-TUPAL044  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPAL020 Measurement of Transverse Dipole and Quadrupole Moments with the BPMS in the J-PARC 3-50 BT quadrupole, dipole, emittance, optics 2197
 
  • T. Toyama
    J-PARC, KEK & JAEA, Ibaraki-ken, Japan
  • H. Kuboki, K. Satou, M. Tejima
    KEK, Tokai, Ibaraki, Japan
 
  We measure dipole and quadrupole moments of the beam using the BPMs in the beam transport line 3-50BT of J-PARC and obtain differences of squared horizontal- and vertical-rms-sizes for those BPMs. Then we obtain rms emittances and rms momentum by fitting with given Twiss parameters.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-WEPAL020  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPAL070 Multi-Physics Analysis of Two Bunchers for CIFNEF cavity, simulation, target, neutron 3815
 
  • Q.Y. Tan, M.J. Easton, Q. Fu, P.P. Gan, H.P. Li, Y.R. Lu, Z. Wang
    PKU, Beijing, People's Republic of China
 
  CIFNEF(Compact Intense Fast NEutron Facility) project will accelerate and deliver a 5 MeV deuteron beam to the targets to produce high-intense neutrons. A 2.5 MHz pulsed deuteron beam with bunch width within 2 ns is needed on the targets at last. To fulfill the special requirements of the beam dynamics, two types of bunchers are adopted in the CIFNEF. One is a 10.156 MHz buncher used in the low energy beam transport (LEBT) line to longitudinally focus the 50 keV deuteron beam to the RFQ longitudinal acceptance with 4 kV effective voltage. A lumped element model is adopted because of the low frequency and it consists of an inductance coil in parallel with the capacitance of drift tube. The other one is an 81.25 MHz buncher used in the high energy beam transport (HEBT) line to longitudinally focus the 5 MeV deuteron beam to 2 ns. A QWR cavity with 2-gaps is used to provide 150 kV effective voltage. Thermal and structural analyses have been carried out on these two bunchers. Details of simulations of these two bunchers are presented and discussed in this paper.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPAL070  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPMF042 Beam Based Measurement of Injection Parameters at KEK-PF injection, kicker, septum, storage-ring 4152
 
  • K. Hirano
    Hiroshima University, Graduate School of Science, Higashi-Hiroshima, Japan
  • K. Harada, N. Higashi, Y. Kobayashi, S. Nagahashi, T. Obina, R. Takai, H. Takaki, A. Ueda
    KEK, Ibaraki, Japan
 
  KEK-PF is a 2.5 GeV synchrotron radiation facility. In recent years, the injection efficiency using conventional pulsed septum and kicker magnets has decreased. The main cause of this problem seems to be the change of the injection parameters due to the accumulation of the errors including the effect of the earthquake on March 11, 2011. For the improvement of the injection efficiency, the precise and detailed parameters of the beam injection under present configuration are essential. In order to fix these parameters, we measure the response of the pulsed magnets by using injected and stored beams. In this presentation, we show the beam based measurement and the simulation results for the PF ring injection system.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2018-THPMF042  