Author: Dupuy, B.
Paper Title Page
S302 Recommissioning of the CERN AD Stochastic Cooling System in 2021 after Long Shutdown 2 20
 
  • W. Höfle, C. Carli, F. Caspers, B. Dupuy, D. Gamba, R. Louwerse, V.R. Myklebust, J.C. Oliveira, L. Ponce, S.F. Rey, L. Thorndahl
    CERN, Meyrin, Switzerland
 
  The power system of the Stochastic Cooling System of the anti-proton decelerator AD at CERN, installed on top of the shielding blocks of the AD ring, was completely dismantled during the long shutdown 2 (LS2) at the end of the 2018 run in order to gain access to the accelerator for magnet consolidation. At start-up, this required finding and verifying the correct delays for all 48 power amplifiers feeding to the two kickers by means of beam transfer functions for the two cooling plateaus at 3.57 GeV/c and 2 GeV/c. We describe the methods used for the setting up and the results of the optimization for the cooling in all three planes, longitudinal, horizontal and vertical. An experimental set-up has been put into operation for the automatic monitoring and correction of the notch position of the longitudinal cooling at 3.57 GeV/c with optical delay lines. We also comment on the lessons learnt during the recommissioning including the repair work for a vacuum leak in the water cooling circuits of the kicker following bake-out and the verification of the internal loads by RF reflectometry.  
slides icon Slides S302 [9.736 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-COOL2021-S302  
About • paper received ※ 02 November 2021       paper accepted ※ 19 December 2021       issue date ※ 06 December 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
S503 AD/ELENA Electron Cooling Experience During and after CERNs Long Shutdown (LS2) 36
 
  • D. Gamba, L. Bojtár, C. Carli, B. Dupuy, A. Frassier, L.V. Jørgensen, L. Ponce, G. Tranquille
    CERN, Geneva, Switzerland
 
  Electron cooling is a key ingredient of the Antimatter Factory at CERN, now composed of the AD and ELENA rings, both featuring an electron cooler. After the successful commissioning of the ELENA ring and electron cooling with antiprotons in 2018, the facility was shut down for the CERN long shutdown (LS2). In the meantime, ELENA has been operating with H ions generated from a local source, and electron cooling of H was demonstrated. The facility has restarted with antiproton operation during summer 2021, and it is now delivering 100 keV production beams through newly installed electro-static extraction lines to all the experiments for the very first time. We will give an overview of the experience gained and difficulties encountered during the restart of the AD and ELENA electron coolers. The experience with electron cooling of H beam in ELENA and the comparison with antiproton cooling will also be presented.  
slides icon Slides S503 [32.064 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-COOL2021-S503  
About • paper received ※ 03 November 2021       paper accepted ※ 01 December 2021       issue date ※ 07 December 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)