A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Gurov, S.M.

Paper Title Page
MOAO10

 Status of VEPP-5 Injection Complex 

  • P.V.Logachev, A.V.Akimov, A.V.Antoshin, P.A.Bak, Yu.M.Boimelshtain, D.Yu.Bolkhovitianov, R.Galimov, S.M.Gurov, E.A.Gusev, N.S.Dikansky, S.N.Klushev, N.Kh.Kot, A.A.Korepanov, I.L.Pivivarov, Yu.I.Semenov, A.N.Skrinsky, A.R.Frolov, A.S.Tsyganov, S.V.Shiyankov
    Budker Institute of Nuclear Physics, Novosibirsk, Russia

The present status of VEPP-5 Injection Complex is presented. The results of VEPP-5 positron source operation are discussed.

19

MODP21

 Beam Position Measurement System In VEPP-5 Preinjector 

  • E.A.Bekhtenev, E.N.Dementev, S.M.Gurov, G.V.Karpov, P.V.Logatchev,A.S.Medvedko
    Budker Institute of Nuclear Physics, Novosibirsk, Russia

A new beam position measurement (BPM) system has been designed, manufactured and tested in VEPP-5 preinjector. This system measures position of single electron and positron bunches for each injection cycle with help of stripline pickups. New BPM electronics provides more high sensitivity with respect to existing one developed in 1998. The system can measure the position of bunches with 108 particles per bunch. The whole dynamic range is from 108 to 5*1010 particles per bunch. The resolution of measurements of single bunch is better than 20 microns for 1010 particles per bunch. The features of system design, the main parameters and results obtained in VEPP-5 preinjector are presented.

250