TUPH19 | A Mechanical Undulator Frame to Minimize Intrinsic Phase Errors | 69 |
|
||
A PrFeB-based cryogenic permanent magnet undu-lator (CPMU) is under construction at the Taiwan Photon Source (TPS) to generate brilliant X-rays. When magnets are cooled to 77 K, a CPMU with a period length of 15 mm can generate an effective magnetic field of 1.32 T in a gap of 4 mm. A main feature of the TPS CPMU is its low-intrinsic-phase errors by the installation of force-compensation modules on the out-of-vacuum girders in a four-support-points configuration. Moreover, adjusting the spring settings one can obtain very low undulator phase errors. In this paper, a mechanical frame design for the TPS-CPMU with force-compensating spring modules will be discussed. Observations of deformation effects of the out-of-vacuum girders on the CPMU will be presented. | ||