Paper |
Title |
Page |
THPH06 |
TMO - a New Soft X-Ray Beamline at LCLS II |
349 |
|
- J.C. Castagna, L. Amores, M. R. Holmes, J.H. James, T.O. Osipov, P. Walter
SLAC, Menlo Park, California, USA
|
|
|
LCLS is building 4 new soft X-ray beamlines with the LCLS-II upgrade. The TMO (Time resolved Molecular Optical science) beamline aka NEH 1.1 will support many ex-perimental techniques not currently available at LCLS. The beamline hinges around 2 main end stations, LAMP a multi configurable end station and DREAM, dedicated to COLTRIM type of experimentation. Both the existing LAMP as well as the newly built DREAM end-station will be configured to take full advantage of both the high per pulse energy from the copper accelerator (120 Hz) as well as high average intensity and high repetition rate (up to 100 kHz) from the superconducting accelera-tor. Each end station will have its own focusing optic systems (KB Mirrors) which can focus the beam down to 300 nm, and have laser pump probe experiments capability. Very demanding requirements for IR and X-ray overlap as well as beam stability, make the TMO beamline a major engineering challenge. The main components of the beamline (KB optics, DREAM end stations and diagnostics components) are built on granite stands. The building struc-ture is being reviewed for thermal stability. First light on TMO is expected in February 2020
|
|
|
Poster THPH06 [0.624 MB]
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-MEDSI2018-THPH06
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|