TUPH41 Investigation of Regulation Plan for the Vibration Utility Equipment of HEPS 136
 
  • F. Yan, D. Ji, Y. Jiao, C. H. Li, Z.Z. Wang, G. Xu
    IHEP, Beijing, People's Republic of China
  • Z. Jiang, L.W. Lai, Q.L. Sun
    SINAP, Shanghai, People's Republic of China
 
  For the third or fourth generation synchrotron light sources, the brilliance of the x-ray beam is 2 to 3 order higher than other generations, and in the meanwhile the beam emittance is at least one order smaller. To ensure the stability of the beam, the vibration caused beam motion is usually controlled to be within 10% of the RMS beam size. Thus the smaller beam emittance is, more restrict of the regulation plan to the vibration sources should be. Inside of the light source site, one major vibration source is the utility equipment such as water pump, compressors and so on. There are two controlling approaches for the vibration amplitude of those sources, one is damping, and another way is decay. However reasonable specification is the key of the controlling method. This work will present the detailed establish process of the regulation plan for HEPS in China.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH41  