An Improved Polarisation Analyser for the I16 Beamline at Diamond |
346 |
|
- M.H. Burt, S.P. Collins, S. Green, I. Horswell, J. Li, G. Nisbet, R. Pocock, J. Spiers, K.G. Wilkinson
DLS, Oxfordshire, United Kingdom
|
|
|
The project to upgrade the I16 polarisation analyser was necessary to increase its functionality and to introduce a more robust construction. The requirement that the analyser was to be mounted on a diffractometer meant the construction needed to be as lightweight and as compact as possible. This provided opportunities to explore new collaborative ways of working with both in-house and external suppliers. The paper describes the approach taken to develop lightweight aluminium vacuum chambers working with a company specialising in additive layer manufacturing. In addition, the design of lightweight and compact slit assemblies are detailed; these were developed in collaboration with a supplier of driven linear stages. A novel requirement for the analyser is to have a detector mounted on a rotation axis in vacuum. The results of working with the in-house detector group to develop a design to with all the necessary thermal and electrical connections are described. The paper also describes further use of additive layer manufacturing to produce prototypes that allows the design of a cable management system to be optimised where previously using 3d CAD models had proved unsatisfactory.
|
|