Author: Trapp, A.
Paper Title Page
TUBA03 The Generic Mirror Chamber for the European XFEL 121
 
  • T. Noll
    BESSY GmbH, Berlin, Germany
  • H. Sinn, A. Trapp
    XFEL. EU, Hamburg, Germany
 
  For the high demanding requirements of the beam-lines of the European XFEL [*] new mirror chambers were developed, designed and tested. A prototype contains the main features of all needed ten units which are tested extensively. The concept of the mirror chamber is a further development of our Cartesian parallel kinematics for X-ray optics in the UHV [**]. The stiffness and vibration behaviour were further improved and the position resolution was increased compared to earlier implementations at Bessy and Flash. For that the drives were redesigned and now feature a stroke of 100 mm with nanometer resolution.
* H. Sinn, TDR: X-Ray Optics and Beam Transport, December 2012, XFEL. EU TR-2012-006 doi:10.3204
** T. Noll, Parallel kinematics for nanoscale Car-tesian motions, Precision Engineering Vol.33/3 Pg.291
 
slides icon Slides TUBA03 [38.484 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2016-TUBA03  
About • paper received ※ 09 September 2016       paper accepted ※ 15 September 2016       issue date ※ 22 June 2017  