Author: Caliari, R.M.
Paper Title Page
MOPE02 Studies on Flow-Induced Vibrations for the New High-Dynamics DCM for Sirius 8
 
  • R.M. Caliari, O.R. Bagnato, F.R. Francisco, R.R. Geraldes, R.L. Parise, M. Saveri Silva, D.O. Tavares, L.,Jr. de Souza
    LNLS, Campinas, Brazil
  • T.A.M. Ruijl
    MI-Partners, Eindhoven, The Netherlands
 
  The monochromator is known to be one of the most critical optical elements of a synchrotron beamline, since it directly affects the beam quality with respect to energy and position. Naturally, the new 4th generation machines, with their small emittances, start to bring about higher stability performance requirements, in spite of factors as high power loads, power load variation, and vibration sources. A new high-dynamics DCM (Double Crystal Monochromator) is under development at the Brazilian Light Source for the Sirius EMA beamline (Extreme Condition X-ray Methods of Analysis). The disturbances induced by the coolant flows are known to be among the most detrimental influences to a DCM performance, however, quantitative force numbers involved in such disturbances are not commonly investigated. According to the novel dynamic concept, these forces should be predictably translated into stability performance. Therefore, experimental setups that allow the indirect measurement of such forces in conditions close to those of operation were designed. The results comparing different indirect cooling profiles and manufacturing processes (brazing and additive manufacturing) are shown.  
poster icon Poster MOPE02 [3.064 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2016-MOPE02  
About • paper received ※ 09 September 2016       paper accepted ※ 15 September 2016       issue date ※ 22 June 2017  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPE19 Mechatronics Concepts for the New High-Dynamics DCM for Sirius 44
 
  • R.R. Geraldes, R.M. Caliari, G.B.Z.L. Moreno
    LNLS, Campinas, Brazil
  • M.J.C. Ronde, T.A.M. Ruijl, R.M. Schneider
    MI-Partners, Eindhoven, The Netherlands
 
  Funding: Brazilian Ministry of Science, Technology, Innovation and Communication
The monochromator is known to be one of the most critical optical elements of a synchrotron beamline. The new 4th generation machines, with emittances in the range of order of 100 pm rad, require even higher stability performances, in spite of the still conflicting factors such as high power loads, power load variation, and vibration sources. A new high-dynamics DCM is under development at LNLS for the future X-ray undulator and superbend beamlines of Sirius. Aiming at inter-crystal stability of a few tens of nrad and considering the limitations of the current DCM implementations, several aspects of DCM engineering are being revisited. The system concept is chosen such that a control bandwidth in the order of 200 to 300 Hz can be achieved. This requires well-designed system dynamics, which can be realized by applying a fundamentally different architecture than that used in common DCM designs, based on principles used in ultra-precision systems for semiconductor manufacturing. As a result, known disturbances can be attenuated or suppressed, and internally excited modes can be effectively handled. The mechatronics concepts and analyses, including the metrological details, are shown.
 
poster icon Poster MOPE19 [5.423 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2016-MOPE19  
About • paper received ※ 11 September 2016       paper accepted ※ 19 September 2016       issue date ※ 22 June 2017  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUCA05 The New High Dynamics DCM for Sirius 141
 
  • R.R. Geraldes, R.M. Caliari, G.B.Z.L. Moreno, L. Sanfelici, M. Saveri Silva, N.M. Souza Neto, H.C.N. Tolentino, H. Westfahl Jr.
    LNLS, Campinas, Brazil
  • T.A.M. Ruijl, R.M. Schneider
    MI-Partners, Eindhoven, The Netherlands
 
  Funding: Brazilian Ministry of Science, Technology, Innovation and Communication
The monochromator is known to be one of the most critical optical elements of a synchrotron beamline, since it directly affects the beam quality with respect to energy and position. The new 4th generation machines, with emittances in the range of order of 100 pm rad, require even higher stability performances, in spite of the still conflicting factors such as high power loads, power load variation, and vibration sources. A new high-dynamics DCM (Double Crystal Monochromator) is under development at the Brazilian Synchrotron Light Laboratory for the future X-ray undulator and superbend beamlines of Sirius. Aiming at an inter-crystal stability of a few tens of nrad (even during the Bragg angle motion for flyscans) and considering the limitations of current DCM implementations, several aspects of the DCM engineering are being revisited. In order to achieve a highly repeatable dynamic system, with a servocontrol bandwidth in the range of 200 Hz to 300 Hz, solutions are proposed for a few topics, including: actuators and guides, metrology and feedback, LN2 indirect cooling, crystal clamping, thermal management and shielding. The concept of this high-dynamics DCM will be presented.
 
slides icon Slides TUCA05 [2.254 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2016-TUCA05  
About • paper received ※ 11 September 2016       paper accepted ※ 20 September 2016       issue date ※ 22 June 2017  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)