Keyword: survey
Paper Title Other Keywords Page
MOPO028 Survey and Alignment System of 100 MeV/100 kW Electron Linear Accelerator quadrupole, target, electron, neutron 87
 
  • O. Bezditko, I.I. Karnaukhov, A.Y. Zelinsky
    NSC/KIPT, Kharkov, Ukraine
 
  For successful operation and working of electron linear accelerator of "NEUTRON SOURCE" driver it is necessary that all the acceleration sections, the quadrupole triplets, the quadrupole lenses, the dipole magnets, the scanning magnets and the chicane should be installed in design position according design parameters. Accuracies of all electromagnetic elements installation are 150 mkm for all three rotation freedom. The whole process, fiducialization and developing of survey net, alignment is controlled by laser tracker Leica AT 401.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2018-MOPO028  
About • paper received ※ 12 September 2018       paper accepted ※ 20 September 2018       issue date ※ 18 January 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPO097 Recent Results for Study of Ceramic and Copper Plating for Power Couplers electron, target, controls, SRF 905
 
  • Y. Yamamoto, E. Kako, S. Michizono
    KEK, Ibaraki, Japan
  • E. Cenni
    CEA/IRFU, Gif-sur-Yvette, France
  • A. Four
    CEA/DRF/IRFU, Gif-sur-Yvette, France
  • Y. Okii
    Nomura Plating Co, Ltd., Osaka, Japan
 
  KEK has conducted a survey to select an optimum ceramic after withdrawal by a domestic manufacturing company two years ago. For this selection, there are four important items on the properties of ceramic; that is, relative permittivity, dielectric loss tangent, surface and volume resistance, and secondary electron emission coefficient. For measurements of these parameters, five kinds of ceramic samples supplied from three companies were measured using three kinds of measurement systems. For measurement of secondary electron emission, scanning electron microscope (SEM) with beam blanking system was used. On the other hand, residual resistivity ratio (RRR) for copper plating, which is the most important item for quality control, has also been carried out while changing plating thickness and acid temperature. In this report, the recent results for these studies will be presented in detailed.  