Author: Xiang, R.
Paper Title Page
THPO125 Runing Status of SRF Gun II at the ELBE Radiation Center 952
 
  • R. Xiang, A. Arnold, P.N. Lu, P. Murcek, J.S. Schaber, J. Teichert, H. Vennekate, P.Z. Zwartek
    HZDR, Dresden, Germany
 
  Funding: The work is supported by the German Federal Ministry of Education and Research (BMBF) grant 05K12CR1 and the Deutsche Forschungsgemeinschaft (DFG) grant XI106/2-1.
As a new electron source with higher brilliance, the second version of the superconducting RF photoinjector (SRF Gun II) has been successfully commissioned at the ELBE Center for High-Power Radiation Sources since 2014. SRF Gun II features an improved 3.5-cell niobium cavity as well as a superconducting solenoid in the same cryomodule. For user operation the SRF Gun II with Mg photocathode successfully generated stable beam with bunch charges up to 200 pC in CW mode, and with sub-ps bunch length. In this presentation the gun’s status and beam parameters will be presented.
 
poster icon Poster THPO125 [1.520 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2018-THPO125  
About • paper received ※ 12 September 2018       paper accepted ※ 20 September 2018       issue date ※ 18 January 2019  