Performance Evaluation of the RF Reference Phase Stabilization System on Fiber-optical Link for KEK e−/e+ Injector LINAC |
230 |
SPWR027 |
|
|
- N. Liu, B. Du
Sokendai - Hayama, Hayama, Japan
- D.A. Arakawa, H. Katagiri, T. Matsumoto, S. Michizono, T. Miura, F. Qiu, Y. Yano
KEK, Ibaraki, Japan
- T. Matsumoto, T. Miura, F. Qiu
Sokendai, Ibaraki, Japan
|
|
|
KEK e−/e+ injector is the 600 m J-shaped LINAC which has 8 RF sectors. Stabilization of RF phase reference for long distance transmission is necessary for stable RF operation. In the present system, single-mode fiber-optical links without feedback control are used from sector 2 to 5. For the SuperKEKB, the phase stability requirement is within 0.1 deg. rms. The more stable RF phase reference is necessary to improve the phase stability. In this paper, a feedback control system for RF reference phase stabilization is tested for system performance evaluation. The temperature and humidity characteristics of the electric and optical components and phase stabilized optical fiber (PSOF) with different wavelengths will also be presented.
|
|
|
Poster MOPO107 [2.026 MB]
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2018-MOPO107
|
|
About • |
paper received ※ 12 September 2018 paper accepted ※ 21 September 2018 issue date ※ 18 January 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
TUPO070 |
Design and Commissioning of KEK New Vacuum Furnace for SRF Cavity Development |
496 |
|
- K. Umemori, M. Egi, E. Kako, T. Konomi, S. Michizono, H. Sakai
KEK, Ibaraki, Japan
|
|
|
Recently new techniques such as Nitrogen-doping and Nitrogen-infusion have been developed to improve performance of SRF (Superconducting RF) cavities. We purchased a new vacuum furnace, which is key to realize these techniques. Cleanness of the furnace is most important issue. The furnace has a cryo-pump and whole of vacuum system is oil-free system. Target vacuum level after cooling down is 1x10-6 Pa. Heater, reflectors and support table were made from Molybdenum to avoid contamination during heat treatment. Metal gaskets are used for all vacuum seals, except big doors. Maximum operation temperature is 1150 degree C. Size is around 1 m diameter and 2m long for a 1.3 GHz 9-cell cavity. Entrance of furnace is covered by a clean booth. The furnace was fabricated, assembled at KEK COI building and commissioned this year. After several burning runs, target vacuum pressure was achieved after cooling down to room temperature. Design of the furnace and performance during commissioning runs are presented.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2018-TUPO070
|
|
About • |
paper received ※ 19 September 2018 paper accepted ※ 21 September 2018 issue date ※ 18 January 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
TUPO071 |
Study on Nitrogen Infusion for 1.3 GHz SRF Cavities Using J-PARC Furnace |
499 |
|
- K. Umemori, T. Dohmae, M. Egi, Y. Hori, E. Kako, T. Konomi, S. Michizono, T. Saeki, H. Sakai, Y. Yamamoto
KEK, Ibaraki, Japan
- J. Kamiya
JAEA/J-PARC, Tokai-mura, Japan
- S. Kurosawa, K. Takeishi
JAEA, Ibaraki-ken, Japan
- T. Okada
Sokendai, Ibaraki, Japan
|
|
|
Nitrogen infusion (N-infusion) is new surface treatment technique for niobium SRF (Superconducting RF) cavities. After cooling down from 800 degree C heat treatment, a vacuum furnace and cavities are kept 120 degree C, 48 hours with about 3 Pa Nitrogen. Improvement of Q-value and accelerating gradient is expected. We used J-PARC furnace, since N-infusion procedure requires clean vacuum furnace. It has a cryo-pump and turbo molecular pumps and its vacuum system is oil-free system. Six times of N-infusion tests were carried out, while changing vacuum condition, N-infusion temperature, Nitrogen pressure, niobium material and so on. Niobium caps were mounted on cavities to avoid contaminations on inner surfaces. Some of trials were successful and vertical test results showed improvement of Q-values and accelerating gradient. However, some of them were not. Most of bad cases showed degradation of Q-values above 5 MV/m. Details of heat treatment procedure including N-infusion and vertical test results are shown in this presentation.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2018-TUPO071
|
|
About • |
paper received ※ 20 September 2018 paper accepted ※ 20 September 2018 issue date ※ 18 January 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
TUPO072 |
First Trial of the In-situ Nitrogen Infusion at KEK |
503 |
|
- T. Konomi, T. Dohmae, E. Kako, S. Michizono, H. Sakai, K. Umemori
KEK, Ibaraki, Japan
- T. Okada
Sokendai, Ibaraki, Japan
|
|
|
The nitrogen infusion is the new surface treatment technique for improving the RF loss and the maximum accelerating gradient of superconducting cavity. In this process, it is important to be carried out continuously both the 800 C annealing in vacuum and 120 C nitrogen infusion without exposure to the atmosphere. The annealing serves activation process by removing the oxide layer. The in-situ nitrogen infusion system was prepared to investigate whether nitrogen infusion effect or something changes happen in the case of applying nitrogen infusion technique without removing the oxide layer. It can only introduce nitrogen into a cavity during 120 C low temperature baking and transport a cavity to the vertical test system without exposure to the atmosphere. We tried to infuse nitrogen to a single cell by keeping 120 C and 48 hours with 3 Pa nitrogen. The cavity was annealed in another furnace and applied high pressure rinsing before nitrogen infusion. The vertical test result was same Q as the normal 120 C baking without nitrogen. It suggests that oxide layer prevents infusion of nitrogen. In this poster, the in-situ nitrogen infusion system and vertical test results will be reported.
|
|
|
Poster TUPO072 [4.653 MB]
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2018-TUPO072
|
|
About • |
paper received ※ 12 September 2018 paper accepted ※ 21 September 2018 issue date ※ 18 January 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
TUPO073 |
Niobium Sample Analysis for Nitrogen Infusion and Doping |
506 |
|
- T. Konomi, E. Kako, S. Michizono, H. Sakai, K. Umemori
KEK, Ibaraki, Japan
- T. Nagata
ULVAC, Inc., Tsukuba, Japan
- T. Nojima
Tohoku University, Sendai, Japan
|
|
|
KEK has been investigating the better conditions of the heat treatment in nitrogen, which are called as nitrogen doping and nitrogen infusion. We have tried to understand the high gradient performance of the cavity from the analyses of samples which were prepared in the same conditions for the cavity. The main tools are D-SIMS for the depth profile of the elemental concentration, XPS for composition analysis and SQUID magnetometry for the critical DC magnetic field measurement. The difference in the depth profiles of the nitrogen, carbon and oxygen between the heat treatment conditions was observed in vacuum and furnace temperature of nitrogen infusion by D-SIMS and XPS. Such a difference correlates with the vortex penetration field measured by SQUID. In particular, that of nitrogen doping sample was greatly degraded, while that of nitrogen infusion sample was slightly improved. The tendency is similar to the RF high gradient test results. Details of the sample analysis are shown in this presentation.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2018-TUPO073
|
|
About • |
paper received ※ 18 September 2018 paper accepted ※ 21 September 2018 issue date ※ 18 January 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
TUPO074 |
Design and Fabrication of KEK Superconducting RF Gun #2 |
510 |
|
- T. Konomi, Y. Honda, E. Kako, Y. Kobayashi, S. Michizono, T. Miyajima, H. Sakai, K. Umemori, S. Yamaguchi, M. Yamamoto
KEK, Ibaraki, Japan
|
|
|
Superconducting RF gun can realize high acceleration voltage and high beam repetition. KEK has been developing the 1.3 GHz elliptical type 1.5 cell superconducting RF gun to investigate fundamental performance. A surface cleaning method and tools are developed by using KEK SRFGUN #1 and high surface peak gradient 75 MV/m was achieved without field emission. SRFGUN #2 which equips the helium jacket and can be operated with electron beam was designed based on the SRFGUN #1. It can be operated with transmit type photocathode which include superconducting transparent material. The cathode plug is cooled by thermal conducting from the 2 K helium jacket and photocathode will be kept around 2K to maintain superconductivity. Bulk niobium photocathode plug and substrate will used for the fundamental performance test. In parallel, the photocathode deposition chamber for multi-alkali photocathode will be prepared.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2018-TUPO074
|
|
About • |
paper received ※ 12 September 2018 paper accepted ※ 20 September 2018 issue date ※ 18 January 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPO003 |
L-band Resonant Ring for Testing RF Windows for ILC |
679 |
SPWR005 |
|
|
- B. Du, N. Liu
Sokendai - Hayama, Hayama, Japan
- T. Matsumoto, S. Michizono, T. Miura, F. Qiu
KEK, Ibaraki, Japan
- T. Matsumoto, T. Miura, F. Qiu
Sokendai, Ibaraki, Japan
|
|
|
A resonant ring is widely used for the breakdown test of RF components under high power. It can reach power gain of more than 10dB, which is limited by the attenua-tion of the ring. An L-band resonant ring is constructed for testing RF components of International Linear Collid-er (ILC) which is based on an RF frequency of 1.3GHz. The target of the high power test is 5 MW. We have fin-ished the test of an input power of 500 W using a solid state amplifier, and the principle of the resonant ring is verified. The resonant ring is tuned to an optimal condi-tion, which is preparation for high power operation. This paper details the principle, construction, and test of the L-band resonant ring.
|
|
|
Poster THPO003 [2.301 MB]
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2018-THPO003
|
|
About • |
paper received ※ 13 September 2018 paper accepted ※ 21 September 2018 issue date ※ 18 January 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPO095 |
Present Status of Capacitor-charging Power Supplies for Klystron Modulators in SuperKEKB Injector Linac |
898 |
|
- M. Kawamura, M. Akemoto, S. Fukuda, H. Honma, S. Michizono, H. Nakajima, T. Natsui, T. Shidara
KEK, Ibaraki, Japan
- H. Akikawa, O. Endo, K. Sato
Nihon Koshuha Co. Ltd, Yokohama, Japan
|
|
|
The capacitor-charging power supplies (CCPSs) for the klystron modulators have been developed from 2002 in the SuperKEKB injector linac. The specifications are that the output voltage is 43kV, the charging power is 30kJ/s, and the output voltage stability is 0.2%p-p. Being used in the old facility, their sizes are restricted in 480mm x 680 mm x 760mm. After various modifications, the 13 CCPSs in the linac have been operated with no fault since last October. The present status of the CCPSs, including the outlines, specifications, and the modifications against the faults, are described.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2018-THPO095
|
|
About • |
paper received ※ 12 September 2018 paper accepted ※ 20 September 2018 issue date ※ 18 January 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPO097 |
Recent Results for Study of Ceramic and Copper Plating for Power Couplers |
905 |
|
- Y. Yamamoto, E. Kako, S. Michizono
KEK, Ibaraki, Japan
- E. Cenni
CEA/IRFU, Gif-sur-Yvette, France
- A. Four
CEA/DRF/IRFU, Gif-sur-Yvette, France
- Y. Okii
Nomura Plating Co, Ltd., Osaka, Japan
|
|
|
KEK has conducted a survey to select an optimum ceramic after withdrawal by a domestic manufacturing company two years ago. For this selection, there are four important items on the properties of ceramic; that is, relative permittivity, dielectric loss tangent, surface and volume resistance, and secondary electron emission coefficient. For measurements of these parameters, five kinds of ceramic samples supplied from three companies were measured using three kinds of measurement systems. For measurement of secondary electron emission, scanning electron microscope (SEM) with beam blanking system was used. On the other hand, residual resistivity ratio (RRR) for copper plating, which is the most important item for quality control, has also been carried out while changing plating thickness and acid temperature. In this report, the recent results for these studies will be presented in detailed.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2018-THPO097
|
|
About • |
paper received ※ 12 September 2018 paper accepted ※ 20 September 2018 issue date ※ 18 January 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|