Paper |
Title |
Page |
MOP02 |
An Optical Diagnostic Beamline for the Bessy II Booster |
19 |
|
- T. Atkinson, J.-G. Hwang, G. Rehm, M. Ries, G. Schiwietz, S. Wiese
HZB, Berlin, Germany
|
|
|
As part of the global refurbishment of the injector at BESSY II, a new optical beamline has been installed in the booster. This paper covers the conceptual design: incorporating the beamline into an operational facility without downtime, the simulation and expectations of the optical transport line, mechanical installation and commissioning with beam. These first results with the present beam delivery system have already achieved source point imaging and bunch length measurements using a fast diode. With the additional PETRA cavity installed for this booster upgrade and connection to acquire RF power in the 2022 summer shutdown planned, the bunch length diagnostics are critical. The beamline will also undergo a final mechanical upgrade and then see the installation of a streak camera.
|
|
|
Poster MOP02 [0.975 MB]
|
|
DOI • |
reference for this paper
※ doi:10.18429/JACoW-IBIC2022-MOP02
|
|
About • |
Received ※ 05 September 2022 — Revised ※ 09 September 2022 — Accepted ※ 11 December 2022 — Issue date ※ 12 December 2022 |
Cite • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
TUP18 |
High-Resolution Interferometric Beam-Size Monitor For Low-Intensity Beams |
265 |
|
- B. Alberdi-Esuain, J.-G. Hwang, T. Kamps
HZB, Berlin, Germany
- T. Kamps
HU Berlin, Berlin, Germany
|
|
|
Plasma-based accelerator technology is reaching a mature state, where applications of the beam for medical sciences, imaging, or as an injector for a future large-scale accelerator-driven light source become feasible. Particularly, the requirements for beam injection into a storage-ring-based light source are very strict with regards to beam quality and reliability. A non-invasive diagnostics greatly helps to reduce the commissioning time of the machine. We present a device suitable for online, non-destructive monitoring of the transverse spot size of the injected beam. In order to measure lateral beam sizes with a few-micrometer resolution, the technique uses an interferometric regime of coherent synchrotron radiation that is enabled by a sub-femtosecond short bunch-length. Simulations of the photon flux and the retrieval of the beam spot-size are performed for different bandwidth filters in order to define the bandwidth acceptance. Results show the potential of the proposed system that achieves precise retrieval of the complex degree of coherence at an extremely low photon intensity similar to those expected towards the plasma-acceleration injectors.
|
|
|
Poster TUP18 [9.961 MB]
|
|
DOI • |
reference for this paper
※ doi:10.18429/JACoW-IBIC2022-TUP18
|
|
About • |
Received ※ 07 September 2022 — Revised ※ 10 September 2022 — Accepted ※ 12 September 2022 — Issue date ※ 03 December 2022 |
Cite • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|