Author: Toral, F.
Paper Title Page
MOPG29 Beam Diagnostics Design for a Compact Superconducting Cyclotron for Radioisotope Production 108
 
  • R. Varela, P. Abramian, J. Calero, P. Calvo, M.A. Domínguez, E.F. Estévez, L. García-Tabarés, D. Gavela, P. Gómez, A. Guirao, J.L. Gutiérrez, J.I. Lagares, D. López, L.M. Martínez, D. Obradors-Campos, C. Oliver, J.M. Pérez Morales, I. Podadera, F. Toral, C. Vázquez
    CIEMAT, Madrid, Spain
 
  Funding: Work supported by the Spanish Ministry of Economy and Competitiveness, project FIS2013-40860-R.
The aim of the AMIT cyclotron is to deliver an 8.5 MeV, 10 μA CW proton beam to a target to produce radioisotopes for PET diagnostics. Such a small cyclotron poses some challenges to the diagnostics design due to its small size. Two sets of diagnostics have been designed, each one aiming at a different phase of the machine lifecycle. During normal operation the stripping foil and the target will be used to measure the current, a dual transverse profile monitor based on a scintillating screen and a Fluorescence Profile Monitor will measure the beam position and the transverse profile. During first stages of commissioning the dual transverse profile monitor and the target will be substituted by an emittance monitor based on a pepperpot. A movable interceptive Beam Probe will be located inside the cyclotron to give information about the beam during acceleration. Additionally, a test bench for the characterization of the beam right after the exit of the ion source has been built with different instruments to measure the beam current and the transverse profile. In this paper the present status of the design, simulation and tests of the diagnostics for the AMIT cyclotron are described.
 
poster icon Poster MOPG29 [2.660 MB]  
DOI • reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-MOPG29  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPG40 Performance Studies of a Single Vertical Beam Halo Collimation System at ATF2 139
 
  • N. Fuster-Martínez, A. Faus-Golfe
    IFIC, Valencia, Spain
  • P. Bambade, A. Faus-Golfe, S. Wallon, R.J. Yang
    LAL, Orsay, France
  • K. Kubo, T. Okugi, T. Tauchi, N. Terunuma
    Sokendai, Ibaraki, Japan
  • K. Kubo, T. Okugi, T. Tauchi, N. Terunuma
    KEK, Ibaraki, Japan
  • I. Podadera, F. Toral
    CIEMAT, Madrid, Spain
 
  Funding: Work supported by IDC-20101074, FPA2013-47883-C2-1-P and ANR-11-IDEX-0003-02
In order to reduce the background that could limit the precision of the diagnostics located in the ATF2 post-IP beamline, a single vertical beam halo collimation system was installed in March 2016. In this paper we present the measurements done in March and May 2016 in order to characterize the collimation system performance. Furthermore, the collimator wakefield impact has also been measured and compared with theoretical calculations and numerical simulations in order to determine the most efficient operation mode of the collimation system in terms of halo cleaning and negligible wakefield impact.
 
DOI • reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-MOPG40  