Author: Nakamura, K.
Paper Title Page
MOPG35 Single Pulse Sub-Picocoulomb Charge Measured by a Turbo-ICT in a Laser Plasma Accelerator 119
 
  • F. Stulle, J.F. Bergoz
    BERGOZ Instrumentation, Saint Genis Pouilly, France
  • W. Leemans, K. Nakamura
    LBNL, Berkeley, California, USA
 
  Funding: The work by the BELLA Center scientists and staff was supported by Office of Science, Office of HEP, US DOE under Contract DE-AC02-05CH11231 and the National Science Foundation.
Experiments at the Berkeley Lab Laser Accelerator (BELLA) verified that the Turbo-ICT allows high resolution charge measurements even in the presence of strong background signals. For comparison, a Turbo-ICT and a conventional ICT were installed on the BELLA petawatt beamline, both sharing the same vacuum flanges. We report on measurements performed using a gas-jet and a capillary-discharge based laser plasma accelerator. In both setups the Turbo-ICT was able to resolve sub-picocoulomb charges.
 
DOI • reference for this paper ※ DOI:10.18429/JACoW-IBIC2016-MOPG35  