Author: Sharma, G.
Paper Title Page
WEP2PT030 Undulator Development Activities at DAVV-Indore 133
 
  • M. Gehlot, R. Khullar, G. Mishra
    Devi Ahilya University, Indore, India
  • H. Jeevakhan
    NITTTR, Bhopal, India
  • G. Sharma
    RI Research Instruments GmbH, Bergisch Gladbach, Germany
 
  Insertion Device Design Laboratory, DAVV has development activities on in-house design, fabrication and measurement of prototype undulators for synchrotron radiation and free electron laser application. The first prototype U50 was built with six periods, 50mm each period. It was PPM type. The next prototype U20 hybrid device based on NdFeB-Cobalt steel was built with aim to produce 0.24T to 0.05T in 10-20mm gap. The undulator is a 20mm period and there are 25 periods. The next one is U50-II PPM structure with 20 periods. In this paper we review the designs of all these undulators and briefly outline the user facilities of Hall probe bench, Pulsed wire bench and stretched wire magnetic measurement systems at IDDL.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-FLS2018-WEP2PT030  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)