A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

van der Horst, B.

Paper Title Page
THPPH007 First RF-Measurements at the 3.5-Cell SRF-Photo-Gun Cavity in Rossendorf 567
 
  • A. Arnold, H. Buettig, D. Janssen, U. Lehnert, P. Michel, K. Moeller, P. Murcek, Ch. Schneider, R. Schurig, F. Staufenbiel, J. Teichert, R. Xiang
    FZR, Dresden
  • T. Kamps, D. Lipka, F. Marhauser
    BESSY GmbH, Berlin
  • G. Klemz
    DESY Zeuthen, Zeuthen
  • W.-D. Lehmann
    IfE, Dresden
  • A. Matheisen, B. van der Horst
    DESY, Hamburg
  • J. Stephan
    IKST, Drsden
  • V. Volkov
    BINP SB RAS, Novosibirsk
  • I. Will
    MBI, Berlin
 
  At the Forschungszentrum Rossendorf the development and the setup of the 2nd superconducting radio frequency photo electron injector (SRF-Photo-Gun) is nearly finished. One of the main attention was focussed at the treatment of the cavity. Their RF properties were measured at room temperature. The warm tuning was carried out considering pre-stressing and tuning range of both tuners (half cell and full cells). The adjusted field profiles and pass band frequencies of the four fundamental modes met the requirements. An external Q study of the main coupler yielded to an optimal antenna length and showed very good agreement between simulation and measurement. Furthermore the characteristics of the choke filter and both HOM filters were simulated, measured and tuned at the pi-mode frequency. The preparation (etching and rinsing) and the cold test were successfully done at DESY. The poster presents the setup for the measurements as well as a comparison of the simulated and measured results. Submitted as poster to the 2006 FEL conference