MOPPH028 Future Seeding Experiments at SPARC 95
 
  • L. Giannessi, S. Ambrogio, F. Ciocci, G. Dattoli, A. Doria, G. P. Gallerano, E. Giovenale, M. Quattromini, A. Renieri, C. Ronsivalle, I. P. Spassovsky
    ENEA C. R. Frascati, Frascati (Roma)
  • D. Alesini, M. E. Biagini, R. Boni, M. Castellano, A. Clozza, A. Drago, M. Ferrario, V. Fusco, A. Gallo, A. Ghigo, M. Migliorati, L. Palumbo, C. Sanelli, F. Sgamma, B. Spataro, S. Tomassini, C. Vaccarezza, C. Vicario
    INFN/LNF, Frascati (Roma)
  • M. Bougeard, B. Carré, D. Garzella, M. Labat, G. Lambert, H. Merdji, P. Salieres, O. Tcherbakoff
    CEA, Gif-sur-Yvette
  • M.-E. Couprie
    SOLEIL, Gif-sur-Yvette
  • A. Dipace, E. Sabia
    ENEA Portici, Portici (Napoli)
  • M. Mattioli
    Università di Roma I La Sapienza, Roma
  • P. Musumeci, M. Petrarca
    INFN-Roma, Roma
  • M. Nisoli, G. Sansone, S. Stagira, S. de Silvestri
    Politecnico/Milano, Milano
  • P. L. Ottaviani, S. Pagnutti, M. Rosetti
    ENEA-Bologna, Bologna
  • L. P. Poletto, G. T. Tondello
    Univ. degli Studi di Padova, Padova
  • L. Serafini
    INFN-Milano, Milano
 
  Sources based on high order harmonics generated in gas with high power Ti:Sa lasers pulses represent promising candidates as seed for FEL amplifiers for several reasons, as spatial and temporal coherence, wavelength tunability and spectral range, which extends down to the 10-9m wavelength scale. This communication is devoted to the description of a research work plan that is under implementation at the SPARC FEL facility in the framework of the EUROFEL programme. The main goal of the collaboration is to study and test the amplification and the FEL harmonic generation process of an input seed signal obtained as higher order harmonics generated both in crystal (400nm and 266 nm) and in gas (266nm, 160nm, 114nm) from a high intensity Ti:Sa laser pulse.  
THPPH031 Commissioning of the SPARC Photo-Injector 637
 
  • M. Bellaveglia, D. Alesini, S. Bertolucci, M. E. Biagini, R. Boni, M. Boscolo, M. Castellano, A. Clozza, L. Cultrera, G. Di Pirro, A. Drago, A. Esposito, M. Ferrario, L. Ficcadenti, D. Filippetto, V. Fusco, A. Gallo, G. Gatti, A. Ghigo, S. Guiducci, M. Incurvati, C. Ligi, M. Migliorati, A. Mostacci, L. Palumbo, L. Pellegrino, M. A. Preger, R. Ricci, C. Sanelli, F. Sgamma, B. Spataro, F. Tazzioli, C. Vaccarezza, M. Vescovi, C. Vicario
    INFN/LNF, Frascati (Roma)
  • A. Bacci, I. Boscolo, F. Broggi, S. Cialdi, D. Giove, M. Mauri, A. R. Rossi, L. Serafini
    INFN-Milano, Milano
  • L. Catani, E. Chiadroni, A. Cianchi, S. Tazzari
    INFN-Roma II, Roma
  • L. Giannessi, M. Quattromini, A. Renieri, C. Ronsivalle
    ENEA C. R. Frascati, Frascati (Roma)
  • M. Mattioli, P. Musumeci, M. Petrarca
    INFN-Roma, Roma
  • A. Perrone
    INFN-Lecce, Lecce
  • J. B. Rosenzweig
    UCLA, Los Angeles, California
 
  The SPARC project is born to perform R&D activity headed to realize SASE-FEL experiments at 500nm and higher harmonic generation. The project foresees the realization of a high brightness photo-injector able to produce a 150-200MeV electron beam to drive FEL process inside a dedicated 14m long undulator. The machine is going to be assembled at LNF and its final configuration is made up of an RF gun, driven by a Ti:Sa laser, injecting into three SLAC type accelerating sections. Nowadays we are working in a photo-injector test phase, aiming to characterize the main hardware components and to investigate the behavior of the e-beam dynamics in the first meters of drift. To do this we utilize the emittance-meter, a home designed diagnostic device placed just after the RF gun, able to move 1.2 meters along the longitudinal axis to measure beam parameters. In this paper we report a more accurate description of the project, the status of the single systems constituting the machine and the most important results we obtained in the e-meter phase.  
THCAU03 Operational Experience with the Emittance-Meter at SPARC 777
 
  • L. Catani, E. Chiadroni, A. Cianchi
    INFN-Roma II, Roma
  • M. Bellaveglia, R. Boni, M. Boscolo, M. Castellano, L. Cultrera, G. Di Pirro, A. Drago, M. Ferrario, D. Filippetto, V. Fusco, A. Gallo, G. Gatti, F. Tazzioli, C. Vaccarezza, M. Vescovi, C. Vicario
    INFN/LNF, Frascati (Roma)
  • M. Migliorati, L. Palumbo
    Rome University La Sapienza, Roma
  • P. Musumeci, M. Petrarca
    INFN-Roma, Roma
  • C. Ronsivalle
    ENEA C. R. Frascati, Frascati (Roma)
 
  We report the operational experience of the movable emittance meter at SPARC. This device is based on the well-known technique of pepper pot (1-D slits in our case) but it allows moving the measuring device along the beam line from about 840 mm to 2200 mm from the cathode, following the emittance oscillations. More than a simple improvement over conventional, though non-trivial, beam diagnostic tools this device defines a new strategy for the characterization of high performance photoinjectors, providing a tool for detailed analysis of the beam dynamics, over a section of the accelerator where emittance compensation take place. With this device we performed detailed and systematic studies on beam dynamics with particular attention to the transverse parameters as well as longitudinal. We report also the operating experience at the PITZ facility.  
slides icon Slides