Yunn, B.
(Byung Yunn)

TUBOS02 Longitudinal Space Charge Effects in the JLAB IR FEL SRF Linac
Carlos Hernandez-Garcia, Kevin Beard, Chris Behre, Stephen Vincent Benson, George Herman Biallas, James Boyce, David Douglas, Fred Dylla, Richard Evans, Al Grippo, Joe Gubeli, David Hardy, Kevin Jordan, Lia Merminga, George Neil, Joe Preble, Michelle D. Shinn, Tim Siggins, Richard Walker, Gwyn Williams, Byung Yunn, Shukui Zhang (Jefferson Lab, Newport News, Virginia)

Observations of energy spread asymmetry when operating the Linac on either side of crest and longitudinal emittance growth have been confirmed by extending PARMELA simulations from the injector to the end of the first SRF Linac module. The asymmetry can be explained by the interaction of the accelerating electric field with that from longitudinal space charge effects within the electron bunch. This can be a major limitation to performance in FEL accelerators.

TUCOS02 High Power Lasing in the IR Upgrade FEL at Jefferson Lab
Stephen Vincent Benson, Kevin Beard, Chris Behre, George Herman Biallas, James Boyce, David Douglas, Fred Dylla, Richard Evans, Al Grippo, Joe Gubeli, David Hardy, Carlos Hernandez-Garcia, Kevin Jordan, Lia Merminga, George Neil, Joe Preble, Michelle D. Shinn, Tim Siggins, Richard Walker, Gwyn Williams, Byung Yunn, Shukui Zhang (Jefferson Lab, Newport News, Virginia), Hiroyuki Toyokawa (KEK, Ibaraki)

We report on progress in commissioning the IR Upgrade facility at Jefferson Lab. Operation at high power has been demonstrated at 5.7 microns with over 4 kW of continuous power output and a recirculated electron beam power of up to 800 kW. We report on the features and limitations of the present design and on efforts to increase the power to over 10 kW.

TUPOS61 Performance and Modeling of the JLab IR FEL Upgrade Injector
Carlos Hernandez-Garcia, Kevin Beard, Stephen Vincent Benson, George Herman Biallas, Don Bullard, David Douglas, Fred Dylla, Richard Evans, Al Grippo, Joe Gubeli, Kevin Jordan, George Neil, Michelle D. Shinn, Tim Siggins, Richard Walker, Byung Yunn, Shukui Zhang (Jefferson Lab, Newport News, Virginia)

The JLab IR Upgrade Injector has delivered up to 9.1 mA CW of electron beam current at 9 MeV. The injector is driven by a 350 kV DC Photocathode Gun. Injector behavior and beam-based measurements are in very good agreement with PARMELA simulations. The injected beam envelopes were established by measuring beam spot sizes and comparing them with those predicted by a transport matrix based model. The emittances were measured by fitting an initial trial beam matrix to the measured data. The injected bunch length was established by measuring the energy spread downstream of the Linac while operating at either side of crest.