Paper | Title | Other Keywords | Page | ||
---|---|---|---|---|---|
PT09 | Cavity-Type BPMs For The TESLA Test Facility Free Electron Laser | diagnostics, instrumentation, free-electron-laser, radio-frequency, undulator | 190 | ||
|
For measurements of the beam position at the undulator section of the
TESLA Test Facility (TTF) at DESY cavity-type beam position monitors were
developed, installed and brought into operation. Besides of some
theoretical aspects results of in-beam measurements at the TTF are
presented and pros and cons of this monitor concept are discussed.
|
|
|