A   B   C   D   E   F   G   H   I   K   L   M   N   O   P   R   S   T   U   W    

TTF

Paper Title Other Keywords Page
PT09 Cavity-Type BPMs For The TESLA Test Facility Free Electron Laser diagnostics, instrumentation, free-electron-laser, radio-frequency, undulator 190
 
  • H. Waldmann, H.J. Schreiber
    DESY-Zeuthen, Deutsches Elektronen-Synchrotron, Zeuthen, Germany
  For measurements of the beam position at the undulator section of the TESLA Test Facility (TTF) at DESY cavity-type beam position monitors were developed, installed and brought into operation. Besides of some theoretical aspects results of in-beam measurements at the TTF are presented and pros and cons of this monitor concept are discussed.