A   B   C   D   E   F   G   H   I   K   L   M   N   O   P   R   S   T   U   W    

booster

Paper Title Other Keywords Page
PT25 Fast Tune Measurement System for the ELETTRA Booster diagnostics, electron, instrumentation, storage-ring 231
 
  • M. Ferianis, S. Bassanese, F. Iazzourene
    ELETTRA, Sincrotrone Trieste, Trieste, Italy
  Since several years, the Diagnostic Group at Laboratori Nazionali di Legnaro (LNL) has been designing Fast Faraday Cups (FFC) to be used on their Heavy Ion Accelerators; latest developments in this field include a stripline FFC, jointly developed with SNS, Oak Ridge. A collaborative partnership has been set-up between LNL and ELETTRA Laboratory to fully characterize new FFCs, using as electron source the ELETTRA 1 GeV Linac. Two FFCs, the stripline FFC, built at SNS, and a coaxial FFC, made at LNL, have been installed at ELETTRA who provided the wideband data acquisition and the remote control of the measurement. The first measurements carried out using 1 GHz oscilloscope allowed the proper set-up of remote control and a low jitter triggering. Wideband measurements were performed with a sampling scope equipped with 50 GHz head whereas the bandwidth of the stripline FFC is in the order of 10 GHz. A complete set of tests has been carried both on the coaxial FFC and on the stripline FFC. Thanks to the information provided by these wideband measurements, the Linac working point has been further optimized as well as the injection process into the ELETTRA SR.