Barth, W.

Paper Title Page
CT02 Single Shot Measurements of the 4-Dimensional Transverse Phase Space Distribution of Intense Ion Beams at the UNILAC at GSI 56
 
  • L. Groening, W. Barth
    GSI, Gesellschaft für Schwerionenforschung, Darmstadt, Germany
  • D.A. Liakin
    ITEP, Institute for Theoretical and Experimental Physics, Moscow, Russia
 
  The UNILAC is used as an injector for the synchrotron SIS. It is designed to fill the synchrotron up to its space charge limit. The upper limit for the useful beam emittance of the UNILAC is given by the finite acceptance of the SIS during the injection process. In order to remain within this acceptance the emittance growth during beam acceleration and transportation due to space charge effects must be minimized by applying an appropriate beam focusing. Therefore, the influence of the magnetic focusing strength on the beam emittance growth was investigated experimentally for different beam currents. Measurements of transverse phase space distributions were performed before and after the Alvarez accelerator with a periodic focusing channel, respectively. In order to perform such a wide parameter scan within a reasonable time with respect to machine stability, the pepper pot technique was applied. The pepper pot method allows for single-pulse measurements. For comparison several measurements using the slit-grid technique, which averages over many pulses, were performed. Both transverse planes were measured simultaneously. Using two pepper pot devices more than 60 single shot measurements of the full 4-dimensional transverse phase space distribution were performed within 8 hours. In this paper we report on the results of the measurements and we compare them to beam dynamic simulations and we give an outlook on further developments on pepper pot devices.  
PM28 Application of Beam Diagnostics for Intense Heavy Ion Beams at the GSI UNILAC 161
 
  • W. Barth, L. Dahl, J. Glatz, L. Groening, S. Richter, S. Yaramishev
    GSI, Gesellschaft für Schwerionenforschung, Darmstadt, Germany
 
  With the new High Current Injector (HSI) of the GSI UNILAC the beam pulse intensity had been increased by approximately two orders of magnitudes. The HSI was mounted and commissioned in 1999; since this time the UNILAC serves as an injector for the synchrotron SIS, especially for high uranium intensities. Considering the high beam power of up to 1250 kW and the short stopping range for the UNILAC beam energies (≤12 MeV/u), accelerator components could be destroyed, even during a single beam pulse. All diagnostic elements had to be replaced preferably by non-destructive devices. The beam current is mainly measured by beam transformers instead of Faraday cups, beam positions are measured with segmented capacitive pick-ups and secondary beam monitors instead of profile harps. The 24 installed pick-ups are also used to measure intensities, widths and phase of the bunches, as well beam energies by evaluating pick-ups at different positions. The residual gas ionization monitors allow on-line measurements of beam profiles. The knowledge of the real phase space distribution at certain position along the linac is necessary for optimizing the machine tuning, for the improvement of the matching to the synchrotron and for a better understanding of beam dynamic issues under space charge conditions. The paper will report the application of different beam diagnostic devices for the measurement of transverse beam emittances at different UNILAC beam energies and for different beam intensities. Additionally, measurements of the bunch structure after the HSI and a the design of a new device for the measurement of the longitudinal emittance at the end of the UNILAC will be included.