| Paper | Title | Other Keywords | Page | ||
|---|---|---|---|---|---|
| PS02 | Bench Test of a Residual Gas Ionization Profile Monitor (Rgipm)
Work supported by U.S. Department of Energy |
instrumentation, diagnostics, emittance, brillance | 102 | ||
|
An RGIPM has been designed, constructed and bench tested to verify that
all components are functioning properly and that the desired resolution
of about 50μm× rms can be achieved. This paper will describe some system
details and it will compare observed results to detailed numerical
calculations of expected detector response.
|
|
|