A   B   C   D   E   F   G   H   J   K   L   M   N   O   P   R   S   T   U   V   W   Y   Z    

Plouviez, E.

Paper Title Page
PS14 Microwave Pickups for the Observation of Multi GHz Signals Induced by the ESRF Storage Ring Electron Bunches 136
 
  • E. Plouviez
    ESRF, European Synchrotron Radiation Facility, Grenoble, France
 
  The length of the bunches stored in ESRF lies in the 30 ps to 120 ps range (FWHM). The observation of single bunch phenomena like transverse or longitudinal oscillations or bunch length variation requires the acquisition and analysis of signals at frequencies higher than 10 GHz. A set of microwave cavity pick ups operating at 10 GHz and 16 GHz together with the appropriate electronics has been implemented on the ESRF storage ring; it detects the wall currents on the vacuum chamber due to the electron beams circulation. We describe the design of these cavities, give the result and analysis of measurements performed with the pick ups and indicate how we plan to use these devices as beam diagnostics