A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Sato, M.

Paper Title Page
THOBAU02 Advances and Performance of Input Couplers at KEK 485
 
  • E. Kako, S. Noguchi, M. Sato, T. Shishido, K. Watanabe, Y. Yamamoto
    KEK, Ibaraki
  • H. Jenhani
    LAL, Orsay
  • T.X. Zhao
    IHEP Beiing, Beijing
 
 

High power tests of the STF cryomodule including four MHI cavities and STF-1 input couplers were carried out at KEK. The maximum input rf power of 360 kW was successfully transfered to the cavity operated at high gradients at 2 K. After the cryomodule tests, the conditioning test of the coupler at room temperature was carried out, and rf processing up to 650 kW (1.5 ms and 5 Hz) was achieved. TTF-V couplers were shipped from LAL to KEK, and the high power test was carried out at KEK-STF. Rf processing up to 2 MW in the short pulse of 400 us (5 Hz) and 1 MW in the long pulse of 1.5 ms (5Hz) was demonstrated. The results of the coupler processing at KEK will be reproted in this talk.

 

slides icon

Slides

 

sound icon

Talk