A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Murcek, P.

Paper Title Page
TUPPO027 The Properties of Normal Conducting Cathodes in FZD Superconducting Cavity 254
 
  • R. Xiang, A. Arnold, H. Büttig, D. Janssen, M. Justus, U. Lehnert, P. Michel, P. Murcek, A. Schamlott, Ch. Schneider, R. Schurig, J. Teichert
    FZD, Dresden
  • F. Staufenbiel
    Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Berlin
 
 

The superconducting rf photoinjector (SRF photoinjector) is one of the latest application of SC technology in the accelerator field. Since superconducting cathodes with high QE are not available up to now, normal conducting cathode material is the main choice for the SRF photoinjectors. However, the compatibility between the cathode and the cavity is one of the challenges for this concept. The SRF gun with Cs2Te cathode has been successfully operated under the collaboration of BESSY, DESY, FZD, and MBI. In this paper, some experience gained in the gun commissioning will be concluded. The results of the properties of Cs2Te photo cathodes in the cavity will be presented, such as the Q.E., life time, regeneracy, dark current and thermal emittance. At the same time, the cavity quality is showed to be steady before and after the cathode working.

 

poster icon

Poster

 
THPPO022 Modified 3+1/2 Cell SC Cavity Made of Large Grain Niobium for the FZD SRF Photoinjector 585
 
  • P. Murcek, A. Arnold, H. Büttig, P. Michel, K. Moeller, J. Teichert, R. Xiang
    FZD, Dresden
  • P. Kneisel
    JLAB, Newport News, Virginia
 
 

An SRF photoinjector has been successfully tested in FZD under the collaboration of BESSY, DESY, FZD, and MBI. In order to improve the gun cavity quality and thus reach a higher gradient, a new 3+1/2 superconducting cavity is being fabricated in cooperation with JLab. The modified cavity is made of large grain niobium, composed of one filter choke, one special designed half-cell (gun-cell) and three TESLA cavities. In this paper, the main updates of the new cavity design will be explained in detail. The deformation of the filter choke and the gun-cell, which is caused by pressure fluctuation in the He-line and also by the effect of the Lorentz force, will be minimized by stiffening between the filter choke and the gun-cell. Meanwhile, the cathode hole in the choke and gun-cell is enlarged for better rinsing. To simplify assembly, the NbTi pick-up will be welded directly on the wall of filter choke.