Paper | Title | Page |
---|---|---|
TUPPO063 | Comparison of Buffered Chemical Polished and Electropolished 3.9 GHz Cavities | 379 |
|
||
Five 3.9 GHz 9 cell cavities have been measured for the DESY FLASH module. These cavities were BCP processed and reached gradients of typically about 25 MV/m with Q drop starting at about 20 MV/m. Recently one cell cavities have been processed with EP and at least one has tested to a gradient of 30 MV/m with Q drop starting at about 25 MV/m. We will compare the results and give an update to the thermal analysis in relation to global thermal breakdown at 3.9 GHz. |
||
|
||
THPPO011 | Design, Fabrication and Testing of Single Spoke Resonators at Fermilab | 550 |
|
||
The Fermilab High Intensity Neutrino Source (HINS) linac R&D program is building a pulsed 30 MeV superconducting H- linac. The linac incorporates superconducting solenoids, high power RF vector modulators and superconducting spoke-type accelerating cavities starting at 10 MeV. This will be the first application and demonstration of any of these technologies in a low-energy, high-intensity proton/H- linac. The HINS effort is relevant to a high intensity, superconducting H- linac that might serve the next generation of neutrino physics and muon storage ring/collider experiments. In this paper we present the RF design, the mechanical design, the fabrication, the chemistry and testing of the first two SSR1 (Single Spoke Resonator type 1) prototype cavities. These cavities operate at 325 MHz with β=0.21. The design and testing of the input coupler and the tuning mechanism are also discussed. |
||
THPPO012 | SRF Cavities for CW Option of Project X Linac | 555 |
|
||
Alternative option of Project X is based on the CW SC 2GeV Linac with the average current 1mA. Possible option of the CW Linac considered in the paper includes low energy part consisted of a few families SC Spoke cavities (from 2.5 MeV to 466 MeV) and high energy part consisted of 2 types of elliptical cavities (v/c=0.81 and v/c=1). Requirements and designed parameters of cavities are considered. |
||
|