A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Rakowsky, G.

Paper Title Page
TH5PFP083 Eddy Current Shielding by Electrically Thick Vacuum Chambers 3398
 
  • B. Podobedov, L. Ecker, D.A. Harder, G. Rakowsky
    BNL, Upton, Long Island, New York
 
 

We investigate AC response of accelerator vacuum chambers to external magnetic field, when the wall thickness is comparable or greater than the skin depth. Good agreement was established between experimental measurements, analytical modeling, and ANSYS simulations. Based on the results we suggest a transfer function model for electrically thick vacuum chambers with arbitrary transverse cross-section.