Paper | Title | Page |
---|---|---|
TH5PFP083 | Eddy Current Shielding by Electrically Thick Vacuum Chambers | 3398 |
|
||
We investigate AC response of accelerator vacuum chambers to external magnetic field, when the wall thickness is comparable or greater than the skin depth. Good agreement was established between experimental measurements, analytical modeling, and ANSYS simulations. Based on the results we suggest a transfer function model for electrically thick vacuum chambers with arbitrary transverse cross-section. |