MOP041 The Superconducting Cw-Linac-Demonstrator at Gsi cavity, linac, solenoid, ion 145
 
  • S. Mickat, W.A. Barth, L.A. Dahl, M. Kaiser
    GSI, Darmstadt
  • K. Aulenbacher
    IKP, Mainz
  • M. Busch, F.D. Dziuba, H. Podlech, U. Ratzinger
    IAP, Frankfurt am Main
  • T. Weilbach
    HIM, Mainz
 
 

GSI applied for a new superconducting (sc) cw-LINAC in parallel to the existing UNILAC. Such a machine is highly desirable with respect to the progress in the field of Superheavy Elements (SHE) for example. The UNILAC at GSI is limited in providing a proper beam for SHE and in fulfilling the requirements for FAIR simultaneously. A sc CH-structure is the key component of the proposed efficient and compact linac. In first vertical rf-tests at the Institute of Applied Physics (IAP) maximum gradients up to 7 MV/m were achieved. The cavities for the cw-LINAC should be operated at 217 MHz providing gradients of about 5.1 MV/m at a total length of minimum 0.6 m . In a first step a prototype of such a sc cw-LINAC as a demonstrator is financed by the Helmholtz Institute Mainz (HIM). The demonstrator is the first section of the proposed cw-LINAC consisting of a sc CH-cavity embedded by two sc solenoids. The aim is a full performance test of the demonstrator with beam at the GSI high charge injector (HLI) in 2013. Presently the tendering of the solenoids, the cavity, the cryostat and the rf-amplifier is in preparation.

 
MOP056 Status of the ALPI Low-beta Section Upgrade cavity, linac, acceleration, vacuum 181
 
  • A. Facco, P. Modanese, F. Scarpa
    INFN/LNL, Legnaro (PD)
  • Y. Ma
    CIAE, Beijing
 
 

The low-beta section of the ALPI linac at Laboratori Nazionali di Legnaro is being upgraded in order to double its energy gain from about 10 MV to 20 MV. This upgrade, performed with a rather limited investment in the background of the standard accelerator activities, is based on the replacement of some rf system components and minor modifications to the cryostats. The cavities, working at 80 MHz, require a 3 dB rf bandwidth of 15 Hz (obtained by means of strong overcoupling) to be locked in the presence of the large Helium pressure fluctuations of ALPI. Their average gradient, although exceeding 6 MV/m at the nominal 7 W power, is presently kept around 3 MV/m during operation, limited by the maximum available rf power in the linac. The ongoing upgrade requires the modification of all low-beta cryomodules to allow new, liquid Nitrogen cooled rf couplers and new, 1 kW amplifiers. A fully equipped prototype cryostat with four, beta=0.047 QWRs has been constructed and tested on line, and operated at 6 MV/m reaching or exceeding all the design goals. The test results will be reported and discussed and the project status will be presented.