THPPC083 Software Tool Leverages Existing Image Analysis Results to Provide In-Situ Transmission of the NIF Disposable Debris Shields 1270
 
  • V.J. Miller Kamm, A.A.S. Awwal, J.-M.G. Di Nicola, P. Di Nicola, S.N. Dixit, D.L. McGuigan, B.A. Raymond, K.C. Wilhelmsen
    LLNL, Livermore, California, USA
 
  Funding: * This work was performed under the auspices of the Lawrence Livermore National Security, LLC, (LLNS) under Contract No. DE-AC52-07NA27344. #LLNL-ABS-632472
The Disposable Debris-Shield (DDS) Attenuation Tool is software that leverages Automatic Alignment image analysis results and takes advantage of the DDS motorized insertion and removal to compute the in-situ transmission of the 192 NIF DDS. The NIF employs glass DDS to protect the final optics from debris and shrapnel generated by the laser-target interaction. Each DDS transmission must be closely monitored and replaced when its physical characteristics impact laser performance. The tool was developed to calculate the transmission by obtaining the total pixel intensity of acquired images with the debris shield inserted and removed. These total intensities existed in the Automatic Alignment image processing algorithms. The tool uses this data, adding the capability to specify DDS to test, moves the DDS, performs calculations, and saves data to an output file. It operates on all 192 beams of the NIF in parallel, and has shown a discrepancy between laser predictive models and actual. As qualification the transmission of new DDS were tested, with known transmissions supplied by the vendor. This demonstrated the tool capable of measuring in-situ DDS transmission to better than 0.5% rms.
 