Author: Varner, G.S.
Paper Title Page
MOCB01 Beam Instrumentation for the SuperKEKB Rings 6
 
  • H. Fukuma, A. Arinaga, J.W. Flanagan, H. Ikeda, H. Ishii, S. Kanaeda, K. Mori, M. Tejima, M. Tobiyama
    KEK, Ibaraki, Japan
  • G. Bonvicini, H. Farhat, R.S. Gillard
    Wayne State University, USA
  • G.S. Varner
    University of Hawaii, Honolulu, HI, USA
 
  The electron-positron collider KEKB B-factory is currently being upgraded to SuperKEKB. The design luminosity of 8 x 1035 /cm2/s will be achieved using beams with low emittance of several nm and doubling beam currents to 2.6 A in the electron ring (HER) and 3.6 A in the positron ring (LER). A beam position monitor (BPM) system of HER and LER will be equipped with super-heterodyne detectors, turn by turn log ratio detectors with fast gates to measure optics parameters during collision operation and detectors of BPMs near the collision point (IP) for orbit feedback to maintain stable collision. New X-ray beam profile monitors based on the coded aperture method will be installed aiming at bunch by bunch measurement of the beam profile. A large angle beamstrahlung monitor detecting polarization of the synchrotron radiation generated by beam-beam interaction will be installed near IP to obtain information about the beam-beam geometry. The bunch by bunch feedback system will be upgraded using low noise frontend electronics and new 12 bits iGp digital filters. An overview of beam instrumentation of SuperKEKB rings will be given in this paper.  
slides icon Slides MOCB01 [8.073 MB]  
 
MOPB72 First Measurements with Coded Aperture X-ray Monitor at the ATF2 Extraction Line 237
 
  • J.W. Flanagan, A. Arinaga, H. Fukuma, H. Ikeda, T.M. Mitsuhashi
    KEK, Ibaraki, Japan
  • G.S. Varner
    University of Hawaii, Honolulu, HI, USA
 
  Funding: Kakenhi
The ATF2 extraction line is used as a test-bed for technologies needed for the ILC final-focus region. An x-ray extraction beam line has been constructed at the final upstream bend before the extraction line straight section, for development and testing of optics and readout systems for a coded aperture-based imaging system. The x-ray monitor is expected to eventually be able to measure single-shot vertical bunch sizes down to a few microns in size at its source location in the ATF2 extraction line. Preliminary scanned measurements have been made with beams in the ~15 micron range, and it is planned to make more measurements with further-tuned beam, and with fast read-out electronics. The details of the layout, expected performance, and preliminary measurement results will be presented.