MOPB70 The Synchrotron Radiation Diagnostic Line at SSRF 232
 
  • J. Chen, Z.C. Chen, G.Q. Huang, Y.B. Leng, K.R. Ye, W.M. Zhou
    SINAP, Shanghai, People's Republic of China
 
  The synchrotron radiation photon beam line has been operated since 2009 at Shanghai Synchrotron Radiation Facility. There are two diagnostic beam lines of the storage ring behind bending magnet, which is employed conventional X-ray and visible imaging techniques. A synchrotron radiation (SR) interferometer using visible light region in order to measure the small transverse electron beam size (about 22μm); low emittance and a low coupling. A small off-axis mirror is set for the convenience of the observation. Wave front testing is used for interferometer to calibrate the deformation effect of optical components. An X-ray pin-hole camera is also employed in the diagnostics beamline of the ring to characterize beam. Typically the point spread function of the X-ray pinhole camera is calculated via analytical or numerical method. Those two methods check each other. As a result, the measurement with SR system has quite enough resolution of itself even though the absolute beam size acquired. The existed system suffers with dynamic problem for beam physics studies. It has been measured 2.8nm.rad in small emittance mode at SSRF.  
 
TUPA22 Design of RF Front End for Cavity Beam Position Monitor based on ICs 383
 
  • B.P. Wang, Z.C. Chen, Y.B. Leng, L.Y. Yu, R.X. Yuan, W.M. Zhou
    SINAP, Shanghai, People's Republic of China
 
  RF front end has the significant impact on the performance of cavity beam position monitor (CBPM) which is indispensable beam instrumentation component in free electron laser(FEL) or linear collider facility. With many new advances in data converter and radio technology, complex RF front end design has been greatly simplified. Now based on digital intermediate frequency (IF) receiver architecture, a new RF front end for (CBPM) has been designed and fabricated using surface mount component on print circuit board (PCB). The front end contains analog-digital converter used to digitize the IF signals. The whole system would be integrated to a digital board developed by our lab to produce the dedicated signal processor for CBPM. There is an Xilinx Vertex-5 FPGA device on the digital board and relevant signal processing algorithm has been implemented on it using VHDL. The details about design and test results would be introduced blow.  
 
MOCB03 Modeling and Performance Evaluation of DCCTs in SSRF 16
 
  • Z.C. Chen, Y.B. Leng, Y. Xiong, W.M. Zhou
    SSRF, Shanghai, People's Republic of China
 
  Direct Current Current Transformer (DCCT) is the most commonly used high precision current monitor in modern particle accelerators including Shanghai Synchrotron Radiation Facility (SSRF). Three types of noise have been observed in the output signal of the DCCT in the storage ring of SSRF: power line noise, beam current related narrow band noise and random square wave noise from nowhere. This article will discuss the noise removal algorithms in SSRF and the performance of the DCCTs afterwards.  
slides icon Slides MOCB03 [1.436 MB]  
 
TUPA07 BPM Selection for Beam Current Monitoring in SSRF 341
 
  • Z.C. Chen, Y.B. Leng, Y.B. Yan
    SSRF, Shanghai, People's Republic of China
 
  Although Direct Current Current Transformer (DCCT) is the general solution of beam current monitor, Beam Position Monitor (BPM) sum signals may still surpass it in some aspects such as the faster data rate and higher resolution in low current situations. Nevertheless, an additional monitor should be harmless. Meanwhile, the DCCTs in the storage ring of Shanghai Synchrotron Radiation Facility (SSRF) have been suffering from various noise and the signals from the BPMs could be an aid to provide the beam current more accurately. There're 140 BPMs in the storage ring in SSRF but not all of them are suitable for this particular usage. This article focuses on the methods used here to dynamicly choose the BPMs that meet the criteria.