MOPA02 |
270 degree Electron Beam Bending System using Two Sector Magnets for Therapy Application |
50 |
|
- S.D. Dhole, S. Akhter, V.N. Bhoraskar, B.J. Patil
University of Pune, Pune, India
- S.T. Chavan, R. Krishnan, S.N. Pethe
SAMEER, Mumbai, India
|
|
|
The 270 degree doubly achromatic beam bending magnet system using two sector magnets has been designed mainly for treating cancer and skin diseases. The main requirements of the design of two magnet system is to focus an electron beam having a spot size less than 3 mm X 3 mm, energy spread within 3% and divergence angle <= 3 mrad at the target. To achieve these parameters the simulation was carried out using Lorentz-3EM software. The beam spot, divergence angle and energy spread were observed with respect to the variation in angles of sector magnets and drift distance. From the simulated results, it has been optimized that the first and second magnet has an angle 195 degree and 75 degree and the drift distance 64 mm. It is also observed that at the 1396, 2878 and 4677 A-turn, the optimized design produces 3324, 6221 and 9317 Gauss of magnetic field at median plane require to bend 6, 12 and 18 MeV electron respectively. The output parameters of the optimized design are energy spread 3 %, divergence angle ~ 2.8 mrad and spot size 2.6 mm.
|
|
|
TUPA06 |
Pulsed Electron Beam Current and Flux Monitor for the Race-track Microtron |
337 |
|
- S.D. Dhole, S. Akhter, V.N. Bhoraskar, B.J. Patil, N.S. Shinde
University of Pune, Pune, India
|
|
|
In electron irradiation experiments on the materials, a true current of the electron beam is to be known to calculate the electron fluence received by the sample. Therefore, a pulsed electron beam current and flux monitor alongwith electronic system for an electron accelerator called Race-Track Microtron has been designed and developed. The sensing device used was a ferrite core having suitable number of turns of copper wire wound around it, through which the electron beam was passed without loss in the intensity. With an appropriate developed electronic circuit, the instantaneous value of the induced voltage was measured which in turn provides value of the electron beam pulsed current. The total charge passed through the ferrite core per unit time was therefore recorded and an integrated value of the total charge in a given period could be derived. This system can be used to measure the electron flux in the range from 108 electron/cm2 to 1016 electron/cm2. Moreover, this system has been used successfully in a few electron irradiation experiments where the knowledge of the electron fluence received by the sample is required.
|
|
|