Maier, M.

Paper Title Page
TH-09 Upgrade of the HIT Injector LINAC-Frontend 183
 
  • S. Yaramyshev, W. Barth, M. Maier, A. Orzhekhovskaya, B. Schlitt, H. Vormann
    GSI, Darmstadt
  • R. Cee, A. Peters
    HIT, Heidelberg
 
 

The Therapy Linac in Heidelberg (HIT) was successfully commissioned in 2006. Required beam parameters were reached except of the beam intensity. The achieved particle transmission for C4+ (design ion) is significantly lower than design. Particle losses are mainly observed in the RFQ. One critical point is the matching section of the RFQ electrodes - Input Radial Matcher (IRM). The original design requires too rigid and narrow beam Twiss-parameters at the RFQ entrance. Also the measured emittance is about twice higher compared to the design. Numerically and experimentally it was proven that the solenoid, used for the beam matching to the RFQ, is not able to provide for the necessary beam size and convergence. As it was shown by beam dynamics simulations using the code DYNAMION, a minor modification of the IRM allows for an improvement of the beam transmission (up to 50%). The proposed measure was realized for an advanced HIT-RFQ-layout, which is recently under test stage. The same modification is already proposed for the linac frontend at Italian Hadrontherapy Center (CNAO, Pavia).

 

slides icon

Slides

 
TH-10 Status of Linac Beam Commissioning for the Italian Hadron Therapy Center CNAO 188
 
  • P. A. Posocco, A. Pisent, C. Roncolato
    INFN/LNL, Legnaro
  • G. Clemente, K.M. Kleffner, M. Maier, A. Reiter, B. Schlitt, H. Vormann
    GSI, Darmstadt
  • G. Balbinot, E. Bressi, M. Caldara, A. Parravicini, M. Pullia, E. Vacchieri, S. Vitulli
    CNAO, Milan
  • C. Biscari
    INFN/LNF, Frascati
  • L. Celona, G. Ciavola, S. Gammino
    INFN/LNS, Catania
 
 

The CNAO (Centro Nazionale di Adroterapia Oncologica), located in Pavia (Italy), is a dedicated clinical synchrotron facility for cancer therapy using high energy proton and Carbon beams. The 400 MeV/u synchrotron is injected by a 216.8 MHz 7 MeV/u linac composed by a low energy beam transport (fed by two ion sources), a 400 keV/u 4-rod type RFQ and a 20 MV IHDTL. The commissioning of the two ECRIS ion sources and the low-energy line was successfully completed at the end of January 2009 reaching the proper beam conditions for injection into the RFQ. After installation and conditioning, the RFQ was commissioned with beam by the GSI-CNAO-INFN team in March 2009. The beam tests results are presented and compared to the design parameters.

 

slides icon

Slides