Author: White, G.R.
Paper Title Page
MOOC02 Cavity BPM System for ATF2 23
 
  • A. Lyapin, R. Ainsworth, S.T. Boogert, G.E. Boorman, F.J. Cullinan, N.Y. Joshi
    JAI, Egham, Surrey, United Kingdom
  • A.S. Aryshev, Y. Honda, T. Tauchi, N. Terunuma, J. Urakawa
    KEK, Ibaraki, Japan
  • J.C. Frisch, D.J. McCormick, J. Nelson, T.J. Smith, G.R. White
    SLAC, Menlo Park, California, USA
  • A. Heo, E.-S. Kim, H.-S. Kim, Y.I. Kim
    KNU, Deagu, Republic of Korea
  • M.C. Ross
    Fermilab, Batavia, USA
 
  In this paper we summarise our 2-year experience operating the Cavity Beam Position Monitor (CBPM) system at the Accelerator Test Facility (ATF) in KEK. The system currently consists of 41 C and S-band CBPMs and is the main diagnostic tool for the new ATF2 extraction beamline. We concentrate on issues related to the scale of the system and also consider long-term effects, most of which are undetectable or insignificant in smaller experimental prototype systems. We consistently show sub-micron BPM resolutions and week-to-week scale drifts of an order of 1%.  
slides icon Slides MOOC02 [2.075 MB]  
 
TUPD61 Multi Optical Transition Radiation System for ATF2 446
 
  • C. Blanch Gutierrez, J. Alabau-Gonzalvo, A. Faus-Golfe, J.J. García-Garrigós
    IFIC, Valencia, Spain
  • J. Cruz, D.J. McCormick, G.R. White, M. Woodley
    SLAC, Menlo Park, California, USA
 
  Funding: FPA2010-21456-C02-00
In this paper we describe the calibration tests, software development and first measurements of a Multi Optical Transition Radiation System in the beam diagnostic section of the Extraction (EXT) line of ATF2, close to the multi wire scanner system. First 2D emittance measurements have been made with success and the system is being used normally for coupling correction. 4D emittance reconstruction algorithm is under improvement and implementation before a systematic measurement campaign and comparison with wire scanners is done. This will be a definitive test of the OTR as a beam emittance diagnostic device, which will give the ability to measure the beam emittance with high statistics, giving a low error and a good understanding of emittance jitter.