Beam Diagnostics for the NSLS-II Booster |
29 |
|
- V.V. Smaluk
BINP, Novosibirsk, Russia
- E.A. Bekhtenev, V.P. Cherepanov, G.V. Karpov, V. Kuzminykh, O.I. Meshkov
BINP SB RAS, Novosibirsk, Russia
- I. Pinayev, O. Singh, K. Vetter
BNL, Upton, Long Island, New York, USA
|
|
|
For successful commissioning and effective operation of the projected NSLS-II Booster, a set of beam diagnostic instruments has been designed. Fluorescent screens are used for the Booster commissioning and troubleshooting. Closed orbit is measured using electrostatic BPMs with turn-by-turn capability. The circulating current and beam lifetime are measured using a DC current transformer. The fill pattern is monitored by a fast current transformer. Visible synchrotron radiation is registered for observation of the beam image. Betatron tunes are measured using two pairs of striplines, the first pair is for beam excitation and the second one – for beam response measurement. Design and performance of the Booster beam instrumentation are described.
|
|
|
MOPD68 |
Pickup Beam Measurement System at the VEPP-2000 Collider |
203 |
|
- Yu. A. Rogovsky, E.A. Bekhtenev
BINP SB RAS, Novosibirsk, Russia
|
|
|
This paper reviews the present state of electromagnetic beam position monitors (pickups) at VEPP-2000 collider. It includes descriptions of position monitors, typical interfaces for these monitors and their system characteristics (resolution, stability, bandwidth and problems or limitations) are discussed. The paper also reviews several types of diagnostic measurements using beam position monitors which are useful in improving accelerator operations.
|
|
|