TUPSM110 | Synchrotron Light Monitor System for NSLS-II | radiation, synchrotron, diagnostics, booster | 478 |
|
|||
A synchrotron light diagnostic beamline has been designed at the NSLS-II storage ring, using the dipole radiations. A "cold-finger" configuration has been selected to block the central x-rays. Beam power on the first mirror is less than 1 W, so no water cooling was required for this in-vacuum mirrors. The beamline layout and major applications will be discussed in this paper. Two vacuum ports are reserved in the NSLS2 booster ring to monitor the transverse profile as well as bunch length measurement during ramping. There will be a synchrotron light port in the BTS transport line for observing the injecting beam behavior during top-up operation. |
|||
WECNB02 | Electro Optical Sampling of Coherent Synchrotron Radiation for Picosecond Electron Bunches With Few pC Charge | laser, electron, radiation, synchrotron | 538 |
|
|||
Electro Optical (EO) sampling is a promising non-destructive method for measuring ultra short (sub-ps) electron bunches. The FEMTO slicing experiment at the Swiss Light Source modulates about 1 pC of the 4-nC electron bunch longitudinally. The coherent synchrotron radiation (CSR) emitted by this substructure was sampled by 100 fs long pulses from an Yb fiber laser in EO crystals of different materials (GaP, ZnTe). The broadening of this ps long structure over several turns of the synchrotron could be measured with sub-ps resolution. |
|||
|