Paper |
Title |
Page |
MOPC004 |
Dynamics of a High Density Ion-Beam with Electron Cooling in HIMAC Synchrotron
|
416 |
|
- T. Uesugi, T. Fujisawa, K. Noda, D. Tann
NIRS, Chiba-shi
- Y. Hashimoto
KEK, Ibaraki
- I.N. Meshkov, E. Syresin
JINR, Dubna, Moscow Region
- S. Ninomiya
RCNP, Osaka
- S. Shibuya, H. Uchiyama
AEC, Chiba
|
|
|
High density circulating-ion beam was obtained with electron-cooling and cool-stacking injection in HIMAC synchrotron. The ion density was saturated at 1.0e9/cm2. Coherent transverse instability was observed when ion- and electron-beam density was high. The dynamics of the cooled ion-beam are described in this report.
|
|
RPAP007 |
Alternating-Phase-Focused Linac with Interdigital H-Mode Structure for Medical Injectors
|
1084 |
|
- Y. Iwata, T. Fujisawa, T. Furukawa, S. H. Hojo, T. Honma, M. Kanazawa, N. M. Miyahara, T. Murakami, M. Muramatsu, K. Noda, H. Ogawa, M. Torikoshi, S. Yamada, K. Yamamoto
NIRS, Chiba-shi
- Y.F. Fujii, T. Mitsumoto, H. Tsutsui
SHI, Tokyo
- T. Fujimoto, H.O. Ogawa
AEC, Chiba
- V.V. Kapin
MEPhI, Moscow
|
|
|
Tumor therapy using Heavy Ion Medical Accelerator in Chiba (HIMAC) has been performed at National Institute of Radiological Sciences (NIRS). With the successful clinical results over ten years, a project on developing compact accelerators has been started. To design these compact accelerators, a size of an injector as well as construction and operation costs plays an important role. To satisfy these requirements, we propose a compact injector consisting of a RFQ and Interdigital H-mode Drift-Tube-Linac (IH-DTL) having the resonant frequency of 200 MHz. The injector will accelerate carbon ion up to 4.0 AMeV. For the beam focusing of the IH-DTL, the method of Alternating-Phase-Focusing was employed. With the IH structure and rather high operating-frequency, the size of the cavities is compact; the radius is approximately 0.4 m, and the length of the RFQ and IH-DTL will be 2.5m and 3.5m respectively. The fabrication of the RFQ is in progress. For the IH-DTL, the full-scale model was fabricated. With the encouraging results of the electric field measurements, we are developing the final design of the IH-DTL. The fabrication of the entire injector will be completed at the end of 2005. The present status of our project will be shown.
|
|
FPAE004 |
Optical Matching of Slowly Extracted Beam with Transport System at HIMAC
|
910 |
|
- T. Furukawa, K. Noda, E. Takada, M. Torikoshi, T.H. Uesugi, S. Yamada
NIRS, Chiba-shi
- T. Fujimoto, M. Katsumata, S. Shibuya, T. Shiraishi
AEC, Chiba
|
|
|
The optical matching between the ring and the transport line plays important role in order to control the beam size and profile after the transport. At HIMAC, thus, we have studied the optical matching of the slowly extracted beam. As a result, it was verified that the beam size of the slowly extracted beam were controlled owing to the optical matching. It was also found that small deviation of quadrupole strength in the ring brings orbit distortion at the transport system.
|
|
FPAE005 |
Characteristics of Injected Beam at HIMAC Synchrotron
|
952 |
|
- T.H. Uesugi, T. Furukawa, K. Noda, S. Shibuya
NIRS, Chiba-shi
|
|
|
At the HIMAC synchrotron, we have carried out the tune survey with the lifetime measurement in order to obtain the high intensity. Under the relatively high intensity, it was observed that a part of the circulating beam was lost due to the coherent oscillation in both the horizontal and the vertical direction. Taking account of the tune shift and spreads, the working point was optimized so as to avoid resonance line. We will describe the experimental result.
|
|