A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Dolgashev, V. A.

Paper Title Page
MOPP083 Status of High Power Tests of Normal Conducting Single-cell Structures 742
 
  • V. A. Dolgashev, S. G. Tantawi
    SLAC, Menlo Park, California
  • Y. Higashi, T. Higo
    KEK, Ibaraki
 
  We report results of ongoing high power tests of single cell traveling wave and standing wave structures. These tests are part of an experimental and theoretical study of rf breakdown in normal conducting structures at 11.4 GHz*. The goal of this study is to determine the gradient potential of normal-conducting, rf powered particle beam accelerators. The test setup consists of reusable mode launchers and short test structures and powered by SLAC’s XL-4 klystron. The mode launchers and structures were manufactured at SLAC and KEK and tested in SLAC klystron test laboratory.

*V. A. Dolgashev, S. G. Tantawi, et al. “High Power Tests of Normal Conducting Single Cell Structures,” SLAC-PUB-12956, PAC07, Albuquerque, New Mexico, 25-29 June 2007, pp 2430-2432.

 
MOPP157 Critical Magnetic Field Determination of Superconducting Materials 919
 
  • A. Canabal, T. Tajima
    LANL, Los Alamos, New Mexico
  • V. A. Dolgashev, S. G. Tantawi
    SLAC, Menlo Park, California
  • T. Yamamoto
    UTNL, Ibaraki
 
  Using a 11.4 GHz, 50-MW, <1 μs, pulsed power source and a TE013-like mode copper cavity, we have been measuring critical magnetic fields of superconductors for accelerator cavity applications. This device can eliminate both thermal and field emission effects due to a short pulse and no electric field at the sample surface. A model of the system is presented in this paper along with a discussion of preliminary experimental data.  
TUPP015 Investigations into Cost Reductions of X-band Instrumentation 1559
 
  • D. Van Winkle, V. A. Dolgashev, J. D. Fox, S. G. Tantawi
    SLAC, Menlo Park, California
 
  The prohibitive costs of commercial test equipment for making fast and accurate pulsed phase and amplitude measurements at X-band result in decreased productivity due to shortages of shared equipment across the test laboratory. In addition, most current set-ups rely on the use of pulsed power heads which do not allow for the measurement of phase thereby limiting the flexibility of available measurements. In this paper, we investigate less expensive in-house designed instrumentation based upon commercial satellite down converters and widely available logarithmic detector amplifiers and phase detectors. The techniques are used to measure X-band pulses with widths of 50 ns to 10’s of usec. We expect a dynamic range of 30-40 dB with accuracies of less than ± 0.1 dB. We show results of the built and tested systems with particular attention focused on temperature performance and accuracy. Block diagrams of the down conversion scheme, and the architecture of a multi-signal X-band RF monitor and measurement system is illustrated. Measured results, and possible modifications and upgrades are presented.  
WEPC023 Ideas for a Future PEP Light Source 2031
 
  • R. O. Hettel, K. L.F. Bane, L. D. Bentson, K. J. Bertsche, S. M. Brennan, Y. Cai, A. Chao, S. DeBarger, V. A. Dolgashev, X. Huang, Z. Huang, D. Kharakh, Y. Nosochkov, T. Rabedeau, J. A. Safranek, J. Seeman, J. Stohr, G. V. Stupakov, S. G. Tantawi, L. Wang, M.-H. Wang, U. Wienands
    SLAC, Menlo Park, California
  • I. Lindau
    Stanford University, Stanford, Califormia
  • C. Pellegrini
    UCLA, Los Angeles, California
 
  With the termination of operation of the PEP-II storage rings for high energy physics at hand, and with the migration of accelerator operation at SLAC in general to photon science applications, a study of the potential conversion of the PEP-II to a future light source has been initiated. With a circumference of 2.2 km and the capability for high current operation, it is clear that operating a converted ring at medium energy (3-6 GeV) could offer very low emittance and an average brightness of order 1022, limited primarily by the power handling capacity of photon beam line optical components. Higher brightness in the soft X-ray regime might be reached with partial lasing in long undulators if the emittance is sufficiently low, and high peak brightness could be reached with seeded FEL emission. Advanced pulsed rf technology might be used to generate short bunches and fast switched polarization in soft X-ray rf undulators. An overview of the preliminary findings of the PEP Light Source study group will be presented, including lattice, X-ray source and beam line options.