A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Yamamoto, M.

  
Paper Title Page
TUPLT072 Dual Harmonic Acceleration with Broadband MA Cavities in J-PARC RCS 1318
 
  • M. Yamamoto
    JAERI, Chiba-ken
  • S. Anami, E. Ezura, K. Hara, Y. Hashimoto, C. Ohmori, A. Takagi, M. Yoshii
    KEK, Ibaraki
  • M. Nomura, A. Schnase, F. Tamura
    JAERI/J-PARC, Tokai-Mura, Naka-Gun, Ibaraki-Ken
 
  In the J-PARC RCS rf system, since the fundamental rf acceleration voltage and the 2nd higher harmonic one are applied to each cavity, the impedance of hte cavity has a broadband characteristic. The Q-value of the cavity is chosen to make the higher harmonic beam loading effect as small as possible. The analysis of the amplifier and the beam loading effect on the dual harmonic rf system is described.  
WEOACH01 High Field Gradient Cavity for J-PARC 3 GeV RCS 123
 
  • C. Ohmori, S. Anami, E. Ezura, K. Hara, Y. Hashimoto, A. Takagi, M. Toda, M. Yoshii
    KEK, Ibaraki
  • M. Nomura, A. Schnase, F. Tamura, M. Yamamoto
    JAERI/J-PARC, Tokai-Mura, Naka-Gun, Ibaraki-Ken
 
  A new type of rf cavity will be used for J-PARC project. To minimize the beam loading effects, the quality factor of the core stack is increased by a cut core configuration. High power test of the rf system has been performed. Temperature rise around the cut surface of the cores were observed. It is minimized by improving the cooling efficiency.  
Video of talk
Transparencies